1/5 Scale Reinforced Concrete Bare Frame with Code Compliant Seismic Detailing, Frame 2
收藏Mendeley Data2024-01-31 更新2024-06-29 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2011-1040.groups/Experiment-2
下载链接
链接失效反馈官方服务:
资源简介:
Similar to the first frame second frame did not have partition walls, however, code compliant ductile reinforcement design was selected. Ductility was controlled by appropriate longitudinal/transverse reinforcement detailing and also by sufficient splice length for longitudinal column reinforcement. A similar pseudo-static test procedure of to first frame is applied. However, target inter-story drift ratios are different. These were 0.7%, 1.1%, 1.5%, 2%, 2.5%, 3.4% on the first story of second frame. Impact hammer excited vibration was applied in a similar manner to the first frame.
创建时间:
2024-01-31