five

2020 Purdue FNR Ecological Sensors Class Air Quality Data

收藏
DataCite Commons2025-12-18 更新2025-04-16 收录
下载链接:
https://purr.purdue.edu/publications/3632/1
下载链接
链接失效反馈
官方服务:
资源简介:
<p>These data are the results of a class project studying air quality. Students in the Purdue Forestry class Ecological Sensors & Data (FNR49800-042). met in Spring 2020. During the spring semester, the COVID-19 lockdown forced students to return home. Students worked at home to deploy a network of air quality sensors using embedded microcontrollers and sensors that are part of the Particle Air Quality Monitoring Kit (https://docs.particle.io/quickstart/aqmk-project/).</p> <p>Sensors included:</p> <ul> <li>Shinyei PPD42 Dust Sensor</li> <li>BME280 Temperature  and Humidity Sensor</li> <li>Seeed Studio Grove Air Quality Sensor v1.3 with metal-oxide sensor.</li> </ul> <p>Students collected either indoor or outdoor data. Location of the data and whether the sensor was located indoors or outdoors is included in the metadata table. Note: locations of sensors are approximate to protect privacy of those with indoor air quality sensors. Sensor data are presented here in a raw, unedited form. Thus, data should subjected to quality control checks to identify data that are compromised by instrument error before use.</p> <p>The time series data are included as a single CSV files. The columns in the CSV file are defined as follows:</p> <ul> <li>site_id: unique site identification for each sensor.</li> <li>Temperature: temperature in °C.</li> <li>Pressure: barometric pressure in pascals.</li> <li>Humidity: percent humidity.</li> <li>Battery Voltage: voltage of the attached battery or other power source.</li> <li>AQ Sensor Slope: An integer value corresponding to increased presence of volatile organic compounds (VOCs) detected by the metal oxide sensor. Values are semi-quantitative and range from 0 to 3.</li> <li>AQ Sensor Raw: A raw value obtained from the metal oxide sensor in millivolts. Increasing values indicate higher levels of VOCs.</li> <li>LPO: Low pulse occupancy. The amount of time during a reading that the dust sensor was detecting particulate matter.</li> <li>Dust Ratio: The LPO value standardized for the amount of time that data were collected.</li> <li>dt: Date and time in Eastern Standard Time (GMT -5).</li> <li>Latitude: Latitude in decimal degrees. May be approximate to protect privacy.</li> <li>Longitude: Longitude in decimal degrees. May be approximate to protect privacy.</li> <li>Location: Indicates whether the sensor was deployed at an "Indoor" or "Outdoor" location.</li> <li>Stove: For "Indoor" locations, indicates what type of stove was present in the household ("Gas" or "Electric"). For outdoor locations, this variable was left blank.</li> </ul>
提供机构:
Purdue University Research Repository
创建时间:
2020-10-27
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作