最小检测压强
收藏国家基础学科公共科学数据中心2024-03-05 收录
下载链接:
https://www.nbsdc.cn/general/dataDetail?id=64edfd31bb16e0300cd4e435&type=1
下载链接
链接失效反馈官方服务:
资源简介:
课题4测量了传感器最小检测压强,裁剪与压力传感器功能区域大小相同的滤纸片(25*25mm2),使用天平精确测量滤纸片质量并求得其提供的接触压强,其次将仿生压力传感器固定于平整平台上,将传感器两侧导线接入数字万用表并进行校正,最后,将滤纸片正对放入传感器功能区域,记录传感器电容变化,计算传感器电容变化ΔC和初始电阻C0之间的比值, 确定传感器的最小检测压强是否小于1Pa。
Task 4 measures the minimum detectable pressure of the pressure sensor. First, cut filter paper sheets with the same size as the functional area of the pressure sensor (25×25 mm²). Precisely weigh the filter paper sheets using an analytical balance and calculate the contact pressure provided by them. Next, fix the biomimetic pressure sensor on a flat platform, connect the wires on both sides of the sensor to a digital multimeter and perform calibration. Finally, place the filter paper sheets directly above the functional area of the sensor, record the capacitance change of the sensor, calculate the ratio between the capacitance change ΔC of the sensor and the initial resistance C0, and determine whether the minimum detectable pressure of the sensor is less than 1 Pa.
提供机构:
华中科技大学
搜集汇总
数据集介绍

背景与挑战
背景概述
该数据集聚焦于仿生压力传感器的最小检测压强测量,通过实验方法验证传感器能否检测小于1帕斯卡的压强,数据量较小(104.71KB),属于国家重点研发计划项目“机器人仿生感知与驱动技术”的成果。
以上内容由遇见数据集搜集并总结生成