Data underlying the publication: Retrieving pulsatility in ultrasound localization microscopy
收藏4TU.ResearchData2022-12-19 更新2026-04-23 收录
下载链接:
https://data.4tu.nl/articles/_/21517878
下载链接
链接失效反馈官方服务:
资源简介:
General information This simulation data belongs to the article: Retrieving pulsatility in ultrasound localization microscopy DOI: 10.1109/OJUFFC.2022.3221354 This information is also available in README.txt, included in this repository. Code availability The scripts that should be used to process this data can be found at: https://github.com/qnano/ulm-pulsatility Data description The simulation data in this repository, is contained in several .zip files: DataSetFig3.zip: This dataset contains the simulation data needed to reproduce Fig. 3 of the article. DataSetR1.zip: This dataset contains the simulation data corresponding to the lateral vessel location R1. It is needed to reproduce Fig 4 and Fig. 6b. DataSetR2.zip: This dataset contains the simulation data corresponding to the lateral vessel location R2. It is needed to reproduce Fig 4 and Fig. 6b. DataSetR3.zip: This dataset contains the simulation data corresponding to the lateral vessel location R3. It is needed to reproduce Fig 4 and Fig. 6b. The .zip folders contain the following: LOTUS_INPUT: This folder contains the input simulated ultrasound images, of which the file names are parametrized as: chunk***.mat: Data set containing IQ variable of size 180x240x1000, containing 1000 B-mode images of dimension 9mmx12mm ULM_results: This folder is initially empty. Results of running the scripts will be stored in this folder. PAR.mat: Parameters with which the ultrasound images are simulated. See scripts for further details. TOTAL_MB.mat: Contains the variable MB_loc_conc that describes the simulated (ground truth) location of the MBs at each frame (z, x) [mm]. Saved MB tracks used for visualization. One of the following options: RAW_tracks.mat Track_r1_illustration.mat Track_r2_illustration.mat Track_r3_illustration.mat GT_theta.mat: Ground truth orientation of the simulated vessels velAv.mat: Average velocity in the simulated vessels during the simulation. Download the desired .zip file and see the documentation at https://github.com/qnano/ulm-pulsatility for instructions on processing the data.
基本信息
本仿真数据集对应论文《超声定位显微成像(ultrasound localization microscopy)中的搏动性提取》(DOI: 10.1109/OJUFFC.2022.3221354),相关说明亦可在本仓库的README.txt文件中查阅。
代码获取
用于处理本数据集的脚本可从以下地址获取:https://github.com/qnano/ulm-pulsatility
数据集说明
本仓库内的仿真数据存储于多个.zip压缩包中:
1. DataSetFig3.zip:包含复现论文图3所需的仿真数据。
2. DataSetR1.zip:包含对应横向血管位置R1的仿真数据,用于复现图4与图6b。
3. DataSetR2.zip:包含对应横向血管位置R2的仿真数据,用于复现图4与图6b。
4. DataSetR3.zip:包含对应横向血管位置R3的仿真数据,用于复现图4与图6b。
各.zip压缩包内包含以下内容:
- LOTUS_INPUT文件夹:存储仿真超声输入图像,文件命名格式为chunk***.mat,该文件包含尺寸为180×240×1000的IQ变量,对应1000幅尺寸为9mm×12mm的B型超声图像。
- ULM_results文件夹:初始为空,运行处理脚本后生成的结果将存储于此。
- PAR.mat:存储仿真超声图像时使用的参数,详细信息请参阅配套脚本。
- TOTAL_MB.mat:包含变量MB_loc_conc,用于描述每帧中微泡(MB)的仿真地面真值位置(z, x)[mm]。
- 可视化用微泡追踪结果文件,包含以下选项之一:RAW_tracks.mat、Track_r1_illustration.mat、Track_r2_illustration.mat、Track_r3_illustration.mat。
- GT_theta.mat:存储仿真血管的地面真值方向信息。
- velAv.mat:存储仿真过程中血管内的平均流速。
请下载所需的.zip压缩包,并参阅https://github.com/qnano/ulm-pulsatility处的文档以获取数据处理操作指南。
提供机构:
Wiersma, Myrthe; Heiles, Baptiste; Maresca, David
创建时间:
2022-12-19



