遇见数据集

Single section of pipe for leak detection

收藏
DataCite Commons2025-06-01 更新2024-07-28 收录
官方服务:

资源简介:

This dataset contains the pressure and flow measurements for a water network with leaks at different locations. The experimental setup consists of a reservoir supplying a <i>1.5kW</i> pump. Water is pumped through a <i>25mm</i> diameter pipe with a length of <i>65m</i> . Leaks are introduced at <i>15m</i> , <i>30m</i> and <i>50m</i> and three different leak sizes are tested at each location. The dataset contains the pressures and flow measurements at the inlet and outlet of the pipe. The dataset is primarily used to investigate the effect of noise and model error for the identification of leaks using model-based leak detection strategies.

本数据集涵盖了带有不同位置泄漏点的供水管网的压力与流量测量数据。实验装置以一座蓄水池为水源,为功率1.5kW的水泵供水,水流经直径25mm、总长65m的管道输送。分别在管道15m、30m和50m位置设置泄漏点,并在每个泄漏位置测试三种不同的泄漏尺寸。本数据集包含管道入口与出口处的压力及流量测量数据。该数据集主要用于探究基于模型的泄漏检测策略在识别泄漏过程中,噪声与模型误差所带来的影响。

提供机构:
figshare
创建时间:
2020-09-18
搜集汇总
数据集介绍
Single section of pipe for leak detection 数据集图片
以上内容由遇见数据集搜集并总结生成