Background
Identifying a specific threshold level of SARS-CoV-2 antibodies that confers protection in immunocompromised patients has been very challenging. The aim was to assess the threshold of 264 binding antibody units (BAU)/ml using four different SARS-CoV-2 antibody assays (Abbott, Beckman, Roche, and Siemens) and to establish a new optimal threshold of protection for each of the four antibody assays.
Methods
This study was performed on data retrieved from 69 individuals, who received at least one dose of the Pfizer/BioNTech BNT162b2 or Moderna COVID-19 vaccine (Spikevax) at the Alphabio Laboratory in Marseille, France (European Hospital, Alphabio–Biogroup). The results were compared to the percent inhibition calculated using a functional surrogate of a standardized virus neutralization test (Genscript).
Results
Samples from 69 patients were analyzed. For a reference cutoff of 264 BAU/ml, assays showed moderate to good overall concordance with Genscript: 87% concordance for Abbott, 78% for Beckman, 75% for Roche, and 88% for Siemens. Overall concordance increased consistently after applying new thresholds, i.e., 148 BAU/ml (Abbott), 48 (Beckman), 559 (Roche), and 270 (Siemens).
Conclusion
We suggest specific adjusted thresholds (BAU/ml) for the four commercial antibody assays that are used to assess pre-exposure prophylaxis in immunocompromised patients.