Raw data for "Multimodal imaging of cubic Cu2O@Au nanocage formation via galvanic replacement using X-ray ptychography and nano diffraction"
收藏NIAID Data Ecosystem2026-03-14 收录
下载链接:
https://zenodo.org/record/7014416
下载链接
链接失效反馈官方服务:
资源简介:
Raw data for "Multimodal imaging of cubic Cu2O@Au nanocage formation via galvanic replacement using X-ray ptychography and nano diffraction"
The file "raw_data_ptychography_waxs.zip" contains one HDF5 archive for each scan. The archives are structured as follows:
section experiment:
identifiers of the lightsource, beamline, beamtime, session number, and scan number
section measured:
N diffraction patterns of size 512x512 px used for ptychography
N WAXS patterns of size 514x1030 px
N scan positions in mm
one detector mask of size 512x512 px used for ptychography
one detector mask of size 514x1030 px used for WAXS
slice separation in mm for multi slice reconstruction
section parameters:
distance between sample and forward detector (ptychography) in mm
pixel size of forward detector (ptychography) in mm
photon energy in keV
cropping of diffraction patterns in px used for ptychographic reconstruction
The following lists show the scan numbers with their corresponding reaction times and slice separations for the in situ series recorded during growth of Cu2O nanocubes, as well as galvanic replacement with Au measured out of focus and in focus.
Growth of Cu2O nanocubes:
scan number
slice distance, mm
reaction time, h
179
1
1.58
185
1
3.59
191
1
4.78
192
1
5.21
193
1
5.64
194
1
6.08
195
1
6.51
196
1
6.94
197
1
7.37
198
1
7.81
199
1
8.24
200
1
8.67
201
1
9.10
202
1
9.53
203
1
9.97
204
1
10.41
205
1
10.86
207
0.96
11.53
208
0.94
11.96
209
0.92
12.41
210
0.9
12.85
211
0.88
13.29
212
0.86
13.74
213
0.84
14.19
215
0.8
15.07
216
0.78
15.50
218
0.74
16.06
219
0.72
16.50
220
0.7
16.82
221
0.68
17.08
223
0.64
17.79
225
0.6
18.53
Galvanic replacement with Au measured out of focus:
scan number
slice distance, mm
reaction time, h
263
1
-0.53
265
1
0.13
266
1
0.38
267
1
0.63
268
1
0.89
269
1
1.14
270
1
1.40
271
1
1.64
272
1
1.90
273
1
2.14
274
1
2.39
275
1
2.63
276
1
2.87
277
1
3.11
278
1
3.35
279
1
3.60
280
1
3.84
281
1
4.08
282
1
4.32
283
1
4.74
284
1
5.15
286
1
5.59
287
1
6.01
288
1
6.35
289
1
6.74
290
1
7.15
291
1
7.55
292
1
7.94
293
1
8.35
294
1
8.75
295
1
9.16
296
1
9.56
297
1
9.96
Galvanic replacement with Au measured in focus:
scan number
slice distance, mm
reaction time, h
117
1
0.33
118
1
0.93
119
1
1.51
120
1
2.08
121
1
2.66
122
1
3.24
123
1
3.87
124
1
4.44
125
1
5.02
126
1
5.61
127
1
6.19
128
1
6.77
129
1
7.35
130
1
7.93
131
1
8.50
The files "waxs_detector_calibration_cu2o_growth.poni" and "waxs_detector_calibration_au_galvanic_replacement.poni" contain the PONI data to be used for azimuthal integration of WAXS patterns using the pyFAI library.
Ptychographic reconstructions
The file "ptychographic_reconstructions.zip" contains the ptychographic reconstructions shown in the article and supplementary information in tiff format.
Stacks of images corresponding to time series:
Figure 1b, 2: P06_Cu2O_growth_scans_00179-00225_entrance_window.tif
Figure 1b, 2: P06_Cu2O_growth_scans_00179-00225_exit_window.tif
Figure 1d, 4, 5: P06_Au_galvanic_replacement_de-focus_scans_00263-00297_exit_window.tif
Figure 5c: P06_Au_galvanic_replacement_in-focus_scans_00117-00131_exit_window.tif
SEM and EDX
The file "SEM_EDX.zip" contains the SEM images and EDX maps shown in Figure 3 in png format. Subfolders indicate the reaction time.
创建时间:
2023-01-14