five

Temperature data pertaining to catalytically supported thermal combustion systems at different flow velocities

收藏
Mendeley Data2024-03-27 更新2024-06-26 收录
下载链接:
https://data.mendeley.com/datasets/5wymp6vm56
下载链接
链接失效反馈
官方服务:
资源简介:
The temperature is determined at catalyst inlet conditions. The system comprises a concentric annular channel, wherein the concentric annular channel further comprises an inner annular channel and an outer annular channel. A platinum catalyst is deposited only upon the interior surface of the inner channel, and the wall of the outer channel is chemically inert and catalytically inactive. The reactant stream flows through the catalytically-coated inner channel and the product stream flows out of the outer non-catalytic channel. Fuel is present for combustion in both the catalytic and non-catalytic channels. The concentrically arranged annular channel is 5.0 mm in inner channel length, 5.6 mm in outer channel length, 0.8 mm in innermost diameter, 2.6 mm in outermost diameter, 0.1 mm in catalyst layer thickness, and 0.2 mm in wall thickness. The spacing between the inner channel and the outer channel is 0.4 mm and remains constant. The system can have any dimension unless restricted by design requirements. All the walls have the same thickness. One of the potential problems associated with the system, as with all micro-scale combustion systems, continues to be combustion stability. Contributor: Junjie Chen, E-mail: koncjj@gmail.com, Department of Energy and Power Engineering, School of Mechanical and Power Engineering, Henan Polytechnic University, 2000 Century Avenue, Jiaozuo, Henan, 454000, P.R. China
创建时间:
2024-01-23
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作