five

Ultrasound Waveforms with and without Ringdown Artifacts

收藏
IEEE2026-04-17 收录
下载链接:
https://ieee-dataport.org/documents/ultrasound-waveforms-and-without-ringdown-artifacts
下载链接
链接失效反馈
官方服务:
资源简介:
Minimally-Invasive Surgeries can benefit from having miniaturized sensors on surgical graspers to provide additional information to the surgeons. One such potential sensor is an ultrasound transducer. At long travel distances, the ultrasound transducer can accurately measure its ultrasound wave's time of flight, and from it, classify the grasped tissue. However, the ultrasound transducer has a ringing artifact arising from the decaying oscillation of its piezo element, and at short travel distances, the artifact blends with the acoustic echo. Without a method to remove the artifact from the blended signal, this makes it impossible to measure the waveform's time of flight.It is possible to use both classical signal processing and deep learning methods to filter raw ultrasound signals, removing the ringing artifact from them, and from the filtered signals, to obtain the time of flight. In this dataset, two datasets are provided to train and test algorithms developed for filtering out the ringdown artifact, and for subsequently extracting the waveform's time of flight. All measured (raw) signals were collected the same experimental setup: an oscilloscope connected to an ultrasound driver to drive a transducer attached to a liquid water container, in an attempt to mimic tissue properties in a tightly controlled environment.The training dataset consists of two groups of signal pairs. The first group consists of 993 signal pairs, with each pair consisting of a raw ultrasound signal (with the acoustic echo blended with the ringing artifact), and a target filtered signal (with only the desired echo). Signals in the first group are sampled at the original sampling frequency of 500 MHz. The second group is like the first group, but with all signals downsampled by a factor of 26. This training dataset includes only travel distances from 2 cm to 4 cm, inclusively, because at these distances in water, the echo is sufficiently separated from the ringdown artifact to be manually extractable. The signal pairs are approximately equally distributed between the distances covered.The test dataset similarly consists of two groups of raw ultrasound signals. The first group consists of 270 signals, collected at 9 travel distances between 0.5 cm and 4.0 cm, with 30 signals per distance. It also includes the associated true times of flight for each distance. Signals in the first group are sampled at the original sampling frequency of 500 MHz. The second group is like the first group, but with all signals downsampled by a factor of 26. All signals in both datasets are aligned.
提供机构:
Sosnovskaya, Yana
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作