five

Stability analysis on flow parameters in coolant temperature control system of lead-cooled fast reactor

收藏
DataCite Commons2025-02-02 更新2025-04-16 收录
下载链接:
https://www.scidb.cn/en/detail?dataSetId=4faac8411dfd4059b2b15085a39ca01c
下载链接
链接失效反馈
官方服务:
资源简介:
Lead-cooled Fast Reactor (LFR), one of the promising nuclear energy technologies for future advanced system, is well foreseen in meeting the goals of Generation IV fission reactor. In LFR, Coolant Temperature Control System (CTCS) is one of the critical parts, and the influence of coolant flow parameters on the stability analysis is worth investigating and studying. In this paper, we use the CLEAR-S, an integrated multifunctional nonnuclear test facility, as reference and the stability analysis of CTCS, concerned to coolant flow rate has been completed based on simplified coolant thermal circulation model. Location of eigenvalues and calculation results of real stability radius, both qualitatively and quantitatively reflect the influence of coolant flow rate on stability respectively. The analysis results show that the feed-water flow rate in steady state is a critical parameter for CLEAR-S, because larger feed water flow rate can improve stability apparently. However, LBE coolant flow rate has little impact on system stability. The results of this work will provide an effective reference for design and operation of LFR.
提供机构:
Science Data Bank
创建时间:
2022-11-27
二维码
社区交流群
二维码
科研交流群
商业服务