five

Enhanced stream greenhouse gas emissions at night and during flood events

收藏
DataCite Commons2025-06-01 更新2024-08-18 收录
下载链接:
https://figshare.com/articles/dataset/Enhanced_stream_greenhouse_gas_emissions_at_night_and_during_flood_events/24439210/1
下载链接
链接失效反馈
官方服务:
资源简介:
Measurements of water parameters of dissolved oxygen (DO), pH, temperature, salinity, water depth, and electrical conductivity (EC) as well as gas samples of carbon dioxide (CO<sub>2</sub>), methane (CH<sub>4</sub>), nitrous oxide (N<sub>2</sub>O), and radon (<sup>222</sup>Rn) were collected through time series apparatus, hourly over 1471 hours and 140 discrete samples of dissolved organic carbon (DOC), Nitrate (NO<sub>3</sub>-), and Ammonium (NH<sub>4</sub>+) were collected exclusively at one site in the headwaters of the stream. A calibrated Hydrolab sonde (Unidata, MS5) measured and logged water temperature (±0.02°C), DO (±0.2 mg/L), EC (±0.02 uS cm @°C), pH (±0.02), and salinity (±0.02) at 10 minute intervals and a ultrasonic doppler (Unidata, Starflow) measured water depth in 15 minute intervals. CO<sub>2</sub>, CH<sub>4</sub>, N<sub>2</sub>O, and<sup> 222</sup>Rn samples were collected through a shower head gas equilibration exchanger. The gas exchanger units (Durridge Company) were set up to receive 3 L/min of stream water. The greenhouse gases of CO<sub>2</sub>, CH<sub>4</sub> and N<sub>2</sub>O were sampled continuously by pumping the equilibrated headspace air from shower head gas equilibration device via a one-way valve to a calibrated cavity ringdown spectroscopy gas analyser (Picarro, G2308, ) with precision of &lt; 3.5 ppb. <sup>222</sup>Rn was measured from the shower head exchanger through a closed air loop to a calibrated Rad7 analyser (Durridge Company, RAD7) (<sup>222</sup>Rn half-life = 3.84 days) and measured at 10 min time steps. Nutrient samples (including duplicates) were collected with a sample-rinsed 60 mL polyethylene syringe. Discrete samples for dissolved organic carbon (DOC) analysis were filtered using pre-combusted 0.7 µm GF/F filters (Whatman), into 40 mL borosilicate vials (USP Type I). Samples for nitrogen were immediately filtered using Satourious ™ 0.45μm cellulose acetate syringe filters into 10 mL polyethylene sample tubes. All samples were kept in a cold icebox, away from light, for less than 5 hours and then frozen until laboratory analysis. Nutrient analysis of DOC was performed with the 40 mL borosilicate vials (USP Type I) first treated with 30 µL of H<sub>3</sub>PO<sub>4</sub> before analysis using an Aurora 1030W TOC Analyser (Thermo Fisher Scientific, ConFLo IV). Nutrient analysis of ammonium (NH<sub>4</sub>+) and nitrate (NO<sub>3</sub>-) was performed on the 10 mL polyethylene sample tubes colourimetrically using a Lachat Flow Injection Analyser.
提供机构:
figshare
创建时间:
2023-10-26
二维码
社区交流群
二维码
科研交流群
商业服务