five

[Luminescence Dataset] The loess sequence of Dolní Věstonice, Czech Republic: A new OSL‐based chronology of the last climatic cycle

收藏
NIAID Data Ecosystem2026-05-01 收录
下载链接:
https://zenodo.org/record/8246532
下载链接
链接失效反馈
官方服务:
资源简介:
Dolní Věstonice - Luminescence Dataset Applicable Licence CC-BY-NC Data curators: Markus Fuchs, Sebastian Kreutzer Reference original work Fuchs, M., Kreutzer, S., Rousseau, D. D., Antoine, P., Hatté, C., Lagroix, F., Moine, O., Gauthier, C., Svoboda, J., and Lisá, L.: The loess sequence of Dolní Věstonice, Czech Republic: A new OSL‐based chronology of the last climatic cycle, Boreas, 42, 664–677, https://doi.org/10.1111/j.1502-3885.2012.00299.x, 2013. How to refer/cite this dataset Please the information auto-generated by Zendo Scope This dataset contains the original luminescence data used to create the chronostratigraphy of the Dolní Věstonice loess profile. By publishing this dataset, we aim to support studies on the general characteristics of luminescence behaviours of natural minerals and support the FAIR guidelines for data sharing. This data is primary unmodified measurement data with all the possible errors and typos! Please note: The dataset was compiled with the greatest care. However, the dataset comes without any guarantee. Human errors are always possible. If you feel that, after reading the original study and this document, the metadata describing the dataset is insufficient, please contact the data curators so that this document can be updated accordingly. Contrary, the primary cannot be updated/modified! Dataset structure The dataset consists of sequence files (SEQ) and measurement data (BIN). To each .bin file, there should be one corresponding sequence file. Measurement data are tagged with sample names in the .bin file, e.g., unless, in case of mistakes, samples can be distinguished in the file.  ...BIN/ BIN/A-VALUE/:measurement data with a-value measurements; the alpha irradiation was partly done on an external source BIN/MAIN/ measurement data with data used to estimate the equivalent dose of each sample BIN/PREHEAT_PLATEAU files with combined preheat and dose recovery test results BIN/MISC various additional measurements as indicated by the name ...SEQ/ SEQ/A-VALUE/ SEQ/MAIN SEQ/PREHEAT_PLATEAU SEQ/MISC ...DE_CSV_EXPORT The extracted equivalent dose values from the measurements with uncertainties in s.  Please note that samples were partly measured on different machines. All files are selections; in the course of the study, we carried out various additional measurements, in particular, preliminary tests; those data are not included in the dataset to keep the dataset comprehensible.  Used abbreviations Abbreviations as used in the measurement and sequence file names. For technical details, we refer to the original study and the reference therein. ABBREVIATION TERM DESCRIPTION CG coarse grain refers to the used grain size fraction, here: 90-200 µm DRT dose-recovery test measurement data with dose recovery test results; in this study, such measurements were carried out in combination with different preheat settings FG fine grain refers to the used grain size fraction, here: 4-11 µm IRSLT Infrared stimulated test test for feldspar contamination LM linear modulation linearly modulated optically stimulated luminescence measurements MAIN main measurement usually, the measurement used to estimate the equivalent dose MG medium grain refers to the used grain size fraction, here: 38-63 µm mz Moritz Name of the used Risø OSL/TL DA-15 reader mx Max Name of the used Risø OSL/TL DA-15 reader NEU neu a German word translating to 'new' oDRT oDRT a typo for just DRT PreaHeat preheat test test against different preheat temperatures Q quartz the measured mineral composition, often in combination with CG , MG , or FG . Example: FGQ : fine grain quartz
创建时间:
2023-08-16
二维码
社区交流群
二维码
科研交流群
商业服务