High-frequency (100 kHz) rectangular bipolar pulses stimulation of individual hippocampal neurons: the effect of electric field
收藏Mendeley Data2024-05-26 更新2024-06-27 收录
下载链接:
https://dandiarchive.org/dandiset/001031/0.240520.1924
下载链接
链接失效反馈官方服务:
资源简介:
This dataset includes recordings of hippocampal neurons stimulated at 100 kHz under various amplitudes (measured as one polarity, V; the peak-to-peak value would be double this amount). Rectangular bipolar pulses were applied continuously for 2 seconds, beginning at 25 ms, with a 50% duty cycle. The pulse amplitude was constant at the indicated voltage. For the electrode configuration used, 1V corresponds to 36 V/cm. Neuron action potentials were visualized using the voltage-sensitive fluorescent dye, FluoVolt. This study was partially supported by NIH grant 15R21EY034803.
创建时间:
2024-05-22