Fluorescence time-lapse images of MDA-MB-231 cells expressing FUCCI(CA)2 (Part 2/2)
收藏DataONE2024-11-20 更新2025-04-26 收录
下载链接:
https://search.dataone.org/view/sha256:80c72ccee9d64bc437b1fae947259ea1af54b5163c7c55ce556a0a17a59245d5
下载链接
链接失效反馈官方服务:
资源简介:
Understanding the details of the cell cycle at the level of individual cells is critical for both cellular biology and cancer research. While existing methods using specific fluorescent markers have advanced our ability to study the cell cycle in cells that adhere to surfaces, there is a clear gap when it comes to non-adherent cells. In this study, we combine a specialized surface to improve cell attachment, the genetically-encoded FUCCI(CA)2 sensor, an automated image processing and analysis pipeline, and a custom machine-learning algorithm. This combined approach allowed us to precisely measure the duration of different cell cycle phases in non-adherent cells.
Our method provided detailed information from hundreds of cells under different experimental conditions in a fully automated manner. We validated this approach in two different Acute Myeloid Leukemia (AML) cell lines, NB4 and Kasumi-1, which have unique cell cycle characteristics. Additionally, we tested the impact of drugs affe..., Images were acquired with a Leica Thunder Imager (Leica Microsystems, Wetzlar, Germany), equipped with a Lumencor Spectra X Light Engine (Lumencor, Beaverton, USA) for fluorescence excitation, a motorized stage and a Leica DFC9000 GTC camera. For non-adherent cells, images were acquired with LAS X software (Leica Microsystems, Wetzlar, Germany, version 3.7.5.24914) using a 10X/0.32NA dry objective. The mCherry and mVenus signals were detected respectively with 540-580 nm and 460-500 nm excitation filters, 585 and 505 nm dichroic mirrors and 592-668 nm and 512-542 nm emission filters. The brightfield channel was also acquired for representation purposes. We imaged 10 fields of views per well and focal points were manually set in each position before starting the acquisition and kept constant during the whole time-lapse thanks to the Adaptive Focus Control (AFC, Leica Microsystems). The total duration of the time-lapse on dherent cells was 120 hours, and the time interval was set to 0.5 h..., , # FUCCI(CA)2\_imaging\_adherent\_cells
[https://doi.org/10.5061/dryad.9s4mw6mrs](https://doi.org/10.5061/dryad.9s4mw6mrs)
## Description of the data and file structure
One hundred thousand MDA-MB-231 cells expressing the FUCCI(CA)2 probe were plated in a Tethis SBS 12-well multi-well plate.
Images were acquired with a Leica Thunder Imager (Leica Microsystems, Wetzlar, Germany).
The mCherry and mVenus signals were detected respectively with 540-580 nm and 460-500 nm excitation filters, 585 and 505 nm dichroic mirrors and 592-668 nm and 512-542 nm emission filters. The brightfield channel was also acquired.
Channel 1: BF
Channel 2: mVenus
Channel 3: mCherry
Pixel size: 650 nm
Z-step: 5.3 um
time-frame: 30 min
total duration: 120h
### Files and variables
Compressed .lif files.
#### **File:** FUCCI\_adherent\_cells\_B1.zip, FUCCI\_adherent\_cells\_B2.zip
**Description:**Â compressed .lif files containing 10 regions (R1-R10), 3 channels (and BF, green and red ), 2 Z planes and...
创建时间:
2024-11-20



