five

Murine kidney glomeruli phosphorylation

收藏
NIAID Data Ecosystem2026-03-09 收录
下载链接:
https://www.omicsdi.org/dataset/pride/PXD000266
下载链接
链接失效反馈
官方服务:
资源简介:
Isolated murine kidney glomeruli were lysed in buffer containing 8M urea, and proteins were reduced and alkylated. Proteins were digested with trypsin. After reverse-phase chomatrography, peptides were fractionated using strong cation exchange chromatography. Phosphopeptides were enriched using IMAC (FeNTA) columns. Peptides were analyzed by LC-MS/MS on a Q Exactive mass spectrometer or an LTQ Orbitrap XL mass spectrometer. Metadata for Orbitrap samples (MaxQuant Output files include „Orbi“) 1. General features – 1.1 Global descriptors a. Responsible person or role: Markus Rinschen. markus.rinschen@uk-koeln.de; tobias.lamkemeyer@uni-koeln.de b. Instrument manufacturer, model: LTQ-Orbitrap XL, Thermo Scientific c. customization 2. Ion sources – ESI fed by nLC 2 (Proxeon) 3. Post source component 3.1. Analyser: MS1 survey scan in an Orbitrap and MS2 analysed in Linear Trap. 3.2. Activation/Dissociation: CID 4. Spectrum and peak list generation and annotation 4.1. Data acquisition: MaxQuant v. 1.3.05 Top one method with a cycle of one full MS1 scan in the Orbitrap, followed by the fragmentation with dynamic exclusion window of 60 seconds and followed by the acquisition of 5 product ion scans generated in the LTQ analyser, and detected in the LTQ. Unselected fragmentation. For further details, see .raw files. URL of file: Filename 4.2. Data analysis: MaxQuant v 1.3.05 Parameters used in the generation of peak lists or processed spectra: see annotation in “parameters” file. The mouse uniprot reference database “complete proteome” obtained on January 2nd, 2013 was used. Metadata for QExactive samples (Max Quant output files include „QE“) 1. General features – 1.1 Global descriptors a. Responsible person or role: Markus Rinschen. markus.rinschen@uk-koeln.de; Marcus Krüger marcus.krueger@mpi-bn.mpg.de b. Instrument manufacturer, model: Q Exactive Thermo Scientific c. customization 2. Ion sources – ESI fed by nLC 1000 (Proxeon) 3. Post source component 3.1. Analyser: MS1 survey scan in an Orbitrap and MS2 analysed in Orbitrap/HCD cell 3.2. Activation/Dissociation: HCD 4. Spectrum and peak list generation and annotation 4.1. Data acquisition: MaxQuant v. 1.3.05 Top one method with a cycle of one full MS1 scan in the Orbitrap, followed by the fragmentation with dynamic exclusion window of 20 seconds in the HCD cell and followed by the acquisition of 10 product ion scans generated in the LTQ analyser, and detected in the LTQ. Unselected fragmentation. For further details, see .raw files. URL of file: Filename 4.2. Data analysis: MaxQuant v 1.3.05 Parameters used in the generation of peak lists or processed spectra: see annotation in “parameters” file. The mouse uniprot reference database “complete proteome” obtained on January 2nd, 2013 was used.
创建时间:
2016-05-09
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作