five

Measurements of guided wave propagation in additively manufactured plates with internal defects obtained by scanning laser vibrometry

收藏
DataCite Commons2025-04-14 更新2025-04-16 收录
下载链接:
https://mostwiedzy.pl/en/open-research-data/measurements-of-guided-wave-propagation-in-additively-manufactured-plates-with-internal-defects-obtained-by-scanning-laser-vibrometry,41007303843844-0
下载链接
链接失效反馈
官方服务:
资源简介:
The DataSet contains guided wave signals measured in additively manufactured samples (plates with the dimensions of 180 x 100 x 3 mm3, made from PLA filament) using scanning laser Doppler vibrometry. The samples were as follows: #1 – with defects visible at the surface; #2 – with internal defects. The measurements of guided waves were performed using the laser vibrometer PSV-3D-400-M (Polytec GmbH) equipped with a VD-07 velocity decoder. The elastic waves were excited using the plate piezoelectric actuator NAC2024 (Noliac). The excitation was a five-cycle wave packet obtained by Hann windowing of a sinusoidal burst with different central frequencies, separatelty, in consecutive measurements: 100 kHz, 200 kHz, and 300 kHz for sample #1 and 100 kHz and 200 kHz for sample #2. Guided wave signals were collected in 87 x 47 = 4089 points distributed on the top surface of the plate. Wave propagation signals for samples #1 to #2 are given in (.csv) files, individually for each excitation frequency. Each file consists of 4090 columns. In the 1st column, time vector (in s) is given. In columns from 2nd to 4090th wave time histories (in m/s) measured in 4089 points are contained.
提供机构:
Gdańsk University of Technology
创建时间:
2025-04-10
二维码
社区交流群
二维码
科研交流群
商业服务