Forced Vibration Test
收藏DataCite Commons2020-08-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2010-0929.groups/Experiment-3
下载链接
链接失效反馈官方服务:
资源简介:
A small eccentric-mass shaker was used to excite the retrofitted structure with harmonic forces. The shaker is comprised of a welded steel frame that is bolted to a steel baseplate, four main bearings, two main shafts, and six attached weights. Eccentricity of the vibrator can be varied between zero and 100% in several increments. The shaker has an operating frequency range of 1-25Hz and a maximum force output of 88 kN.
The response of the structure was recorded using tri-axial accelerometers. By developing a frequency response function (FRF) from the data, the modal frequencies could be directly estimated from peak-picking, and the modal damping ratios could be found using the half-power bandwidth method.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2013-04-19