Samsung INR21700-50E Capacity and HPPC tests
收藏NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/10891870
下载链接
链接失效反馈官方服务:
资源简介:
Samsung INR21700-50E Capacity and HPPC tests
Dataset containing 444 samples of Hybrid Pulse Power Cycle (HPPC) tests of Samsung INR21700-50E cells from former micromobility applications. The cells are presorted with different State of Health categories: 95% SoH <= SoH < 100% and 90% <= SoH <= 95%. Furthermore, some new cells were tested for comparison.
The dataset contains charge and discharge tests for 143 cells, combined with a HPPC discharge microcycle at every 10% State of Charge decrement. The remaining cells are tested with a single HPPC microcycle.
The following test protocol was used for the 143 cells:
Wait until the temperature inside the chamber, reaches thermal equilibrium, i.e., 25 °C
Charge the cell in CC/CV-mode with C/2 and Icutoff at 98 mA
Wait at least one hour or until thermal equilibrium
Discharge the cell with C/5 until 2.5 V is reached (obtain discharge capacity of the cell)
Wait at least one hour or until thermal equilibrium
Charge the cell in CC/CV-Mode with C/2 and Icutoff at 98 mA
Wait at least one hour or until thermal equilibrium
Perform a HPPC in combination with discharge
Perform a HPPC micro cycle with SOC at 100 percent (shutdown criteria must be softened for this step)
Discharge by 10% SOC until 2.5 V is reached
Perform a HPPC micro cycle (switch polarity after reaching 50% SOC). Stop the cycle if 2.5 V is reached. Wait for 30 minutes after the micro cycle
Try to discharge until 2.5 V is reached
Wait until thermal equilibrium is reached
Charge the cell in CC/CV-mode with ¾ C and Icutoff at 98 mA
Charge and discharge were recorded with 100 Hz. HPPC cycles were recorded with 1 kHz. Temperature was measured at the middle of the cell.
Recorded values: Time [timestamp], ClimaTemp [temperature sensor of climate chamber], I [A, current], Itarget [A, setpoint for current], P [W, power], Q [As, charge, total], Qneg [As, negative charge], Qpos [As, positive charge], Temp[1] [°C, cell temperature], U [V, cell voltage], hp_pulse [variable for start and end of HPPC pulses]
创建时间:
2024-06-20