Lasius niger highres microCT
收藏Figshare2022-11-03 更新2026-04-08 收录
下载链接:
https://figshare.com/articles/dataset/Lasius_niger_highres_microCT/21482898/1
下载链接
链接失效反馈官方服务:
资源简介:
After CPD the heads were carefully mounted on the tip of a glass syringe using a hot glue gun. A nanotom m (GE Measurement & Control, Wunstorf, Germany), equipped with an X-ray cone beam setup was used for scanning. Magnifications were defined through geometrical relations that based on the distances between sample, source and detector. The heads were scanned at a voltage of 110 kV, 120 μA current and 0.75 s exposure time at an averaging of 4, which resulted in a scanning time of 90 minutes and 1500 number of projections acquired during scan. The tomographic reconstruction was performed using the standard parameters offered by the phoenix datos|x 2.2 reconstruction software on a separate workstation. <em>L. niger</em>: resulted in a voxel size of 0.805 µm.