five

Rocking Wall-Floor-Column Subassemblage Pseudo-Static Cyclic Test at NEES@UMN (MAST) Specimen 2

收藏
DataCite Commons2020-08-19 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2010-0946.groups/Experiment-11
下载链接
链接失效反馈
官方服务:
资源简介:
A large scale subassemblage test was conducted at NEES@UMN (MAST) to investigate the “vertical movement isolation” wall‐floor connection concept and the interaction of the rocking wall with the surrounding structural systems, including slabs and columns. The quasi‐static nature of MAST prevents investigation of dynamic energy losses associated with wall rocking. Test was conducted on 1/3‐scale portions of the prototype structures featuring PreWEC systems attached to one story 10’x20’ floor diaphragm in plan. Steel trusses were utilized in the test to constrain the deformed shape of the 1st story columns. Lateral drift up to 5% was applied to the specimen. The PreWEC and floor were extensively instrumented to observe the specimen behavior including 177 strain gauges, 58 Linear Variable Differential Transformer (LVDT) devices, 26 String Pots,10 DCDT and 13 load cells. Test results will be used to evaluate the performance of the PreWEC and floor systems and the analytical models.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2015-03-27
二维码
社区交流群
二维码
科研交流群
商业服务