Virtual cohort of adult healthy four-chamber heart meshes from CT images
收藏NIAID Data Ecosystem2026-03-13 收录
下载链接:
https://zenodo.org/record/4590293
下载链接
链接失效反馈官方服务:
资源简介:
Dataset Description: We present the first database of four-chamber healthy heart models suitable for electro-mechanical (EM) simulations. Our database consists of twenty four-chamber heart models generated from end-diastolic CT acquired from patients who went to the emergency room with acute chest pains. Since no cardiac conditions were detected in follow-up, these patients were taken as representative of "healthy" (or asymptomatic) hearts. These meshes were used for EM simulations and to build a statistical shape model (SSM). The output of the simulations and the weights of the SSM are also provided.
Cardiac meshes: We segmented end-diastolic CT. The segmentation was then upsampled and smoothed. The final multi-label segmentation was used to generate a tetrahedral mesh. The resulting meshes had an average edge length of 1 mm. The elements of all the twenty meshes are labelled as follows:
Left ventricle myocardium
Right ventricle myocardium
Left atrium myocardium
Right atrium myocardium
Aorta wall
Pulmonary artery wall
Mitral valve plane
Tricuspid valve plane
Aortic valve plane
Pulmonary valve plane
Left atrium appendage "inlet"
Left superior pulmonary vein inlet
Left inferior pulmonary vein inlet
Right inferior pulmonary vein inlet
Right superior pulmonary vein inlet
Superior vena cava inlet
Inferior vena cava inlet
Left atrial appendage border
Right inferior pulmonary vein border
Left inferior pulmonary vein border
Left superior pulmonary vein border
Right superior pulmonary vein border
Superior vena cava border
Inferior vena cava border
Ventricular fibres were generated using a rule-based method, with a fibre orientation varying transmurally from endocardium to epicardium from 80˚ to -60˚, respectively. We defined a system of universal ventricular coordinates on the meshes: an apico-basal coordinate (Z) varying continuously from 0 at the apex to 1 at the base (defined with the mitral and tricuspid valve); a transmural coordinate (\(\rho\)) varying continuously from 0 at the endocardium to 1 at the epicardium; a rotational coordinate (\(\phi\)) varying continuously from – π at the left ventricular free wall, 0 at the septum and then back to + π at the left ventricular free wall; intra-ventricular coordinate (V) defined at -1 at the left ventricle and +1 at the right ventricle. This coordinate system was assigned to the ventricles in the four-chamber meshes and all the other labels were assigned with -10.
We provide a zipped folder for each mesh, A VTK file for each mesh was included (in ASCII) as an UNSTRUCTURED GRID. In all the cases the following fields were included:
POINTS, with the coordinates of the points in mm.
CELL_TYPES, having all of the points the value 10 since they are tetrahedra.
CELLS, with the indices of the vertices of every element.
CELL_DATA, corresponding to the meshing tags.
VECTORS, with the directions of the fibres.
POINT_DATA, with four LOOKUP_TABLE subfields corresponding to the UVC in the order \(\rho\), \(\phi\), Z and V.
Cardiac simulations: For the cardiac EM simulations we used CARP (Cardiac Arrhythmia Research Package). We used the reaction-eikonal model for electrophysiology, stimulating as initial condition the bottom third (Z < 0.33) of the endocardium. We simulated the large deformation mechanics in a Lagrangian reference system. The ventricular myocardium was modelled as a hyperelastic transversely isotropic material with Guccione's strain energy function. The remaining tissues were modelled as non-contracting neo-Hookean materials. Simulations of meshes #09 and #10 failed to converge. Details on the specific parametrisation can be found in the supplements of the reference paper.
We provide comma-separated-values files with the output of the simulations used in the reference paper for validation purposes. The simulations of the cases that did not converge were not included. The acronyms used in the names of columns are:
EDP: End-diastolic pressure
EDV: End-diastolic volume
Myo_vol: Myocardial volume of the ventricle (as sum of its elements)
ESV: End-systolic volume
SV: Stroke volume
EF: Ejection fraction
V1: Volume at time of peak flow
EF1: First-Phase Ejection Fraction
ESP: End-systolic pressure
dPdtmax: Maximum increase of pressure
dPdtmin: Maximum decrease of pressure
PeakP: Peak pressure
tpeak: Time to peak pressure
ET: Ejection time
ICT: Isovolumic contraction time
IRT: Isovolumic relaxation time
tsys: Duration of systole
QRS: QRS duration
AT1090: Time taken to activate from 10% to 90% of the mesh
AT: Activation time of the left ventricle
Besides the output value name, in each column is specified the ventricle where that output was extracted from with the suffixes "_LV" or "_RV".
Statistical shape model: All the meshes but #20 were used to build a statistical shape model of four-chambers cardiac meshes. In short, we rigidly aligned the meshes and extracted the surfaces, representing them as deRham currents. The registration between meshes and computation of the average shape (also called atlas or template) was done using a Large Deformation Diffeomorphic Metric Mapping method. Each one of the meshes can be approximated as a linear combination of the shape modes, extracted using Principal Component Analysis on the space where the meshes are located. More details on the Statistical Shape Model are provided in the supplement of the reference paper. The average heart and extreme cases are provided in the repository named "Virtual cohort of extreme and average four-chamber heart meshes from statistical shape model". We have added 1000 more meshes from the same statistical shape model, modifying the weights from the PCA randomly within the 2SD range. These meshes are provided in the repository named "Virtual cohort of 1000 synthetic heart meshes from the adult human healthy population".
We provide the weights of the modes for each of the 19 meshes in a comma-separated-values file.
创建时间:
2022-05-06



