Data and analysis code for: Material-dependent spectral transmission in a mechanically excited, piezo-sensed EEG phantom

收藏
Zenodo2026-08-16 更新2026-08-20 收录
官方服务:

资源简介:

Complete data and analysis package for a study of a mechanically excited, piezo-sensed EEG phantom with interchangeable steel and PLA transmission beams. CONTENTS data_raw/ — 60 raw OpenBCI Cyton serial exports (8 EXG channels, 250 Hz), one per condition: material (steel, PLA) x beam position (top, middle, bottom) x commanded excitation frequency (1–10 Hz). Turkish filename stems: alt = bottom, orta = middle, ust = top, demir = steel. code/ — the full analysis pipeline. analyze_piezo_ml_hp1.py is the primary chain (zero-phase fourth-order 1–40 Hz Butterworth band-pass); analyze_piezo_ml_reference.py is the 0.5 Hz comparison reported in Section 3.6; plus the group-preserving label-permutation test, feature ablation, leave-one-frequency-out and leave-one-position-out sensitivity analyses, the Euler-Bernoulli beam model, and the figure scripts. A MATLAB reference implementation is included under code/matlab/. results/ — run-level feature tables for both high-pass settings, quality-control report, permutation null distributions, ablation results, held-out block predictions, and the processing-sensitivity comparison. figures/, tables/ — the published figures and tables. REPRODUCING THE PRIMARY ANALYSIS pip install numpy scipy scikit-learn pandas matplotlib seaborn openpyxl python code/analyze_piezo_ml_hp1.py data_raw results_reproduced EXTERNAL DATA Figure 3 additionally uses the eyes-closed baseline records of subjects S001–S030 of the PhysioNet EEG Motor Movement/Imagery Database v1.0.0 (doi:10.13026/C28G6P), under the Open Data Commons Attribution License v1.0. Those human recordings are not redistributed here; code/fetch_physionet.py downloads them and records SHA-256 checksums for all 30. KNOWN LIMITATIONS OF THIS DATASET Drive voltage, coupling force, beam insertion depth and boundary condition, the physical channel-to-sensor map, and reference/ground placement were not recorded. Each condition was acquired once, so the data support cross-condition comparison but not repeatability estimation. Amplitude values are instrument-scale and not independently calibrated. LICENCE Data, figures and tables: CC BY 4.0. Code: MIT. See LICENSE-DATA.txt and LICENSE-CODE.txt. FUNDING Scientific Research Projects Coordination Unit of Süleyman Demirel University, project FDK-2022-8789.

提供机构:
Zenodo
创建时间:
2026-08-16
二维码
社区交流群
二维码
科研交流群
商业服务