遇见数据集

Three-Phase Power Flow Dataset for the Brazilian PAI14 Distribution Feeder (Araraquara)

收藏
Zenodo2026-03-10 更新2026-05-26 收录
官方服务:

资源简介:

Repository Description This document describes the columns and data structure of each file used to model the real Brazilian distribution feeder analyzed in the associated research article. The dataset contains the input data required to reproduce the feeder model and the simulations presented in the paper "Fast and Scalable Three-Phase Voltage Sensitivity Method for Unbalanced Distribution Networks", submitted to IEEE Access. Support and questions: cristhiangro@gmail.com Data Files Description The dataset is organized into several files describing the electrical components of the distribution system, including buses, branches, transformers, switches, generators, and base values. DATA_BUS.DAD This file contains the bus data of the distribution network. nBusID Area phases ID_Real DESCRICAO Type Z I P Vnom Connection VLN(a)[pu] Deg(a)[deg] VLN(b)[pu] Deg(b)[deg] VLN(c)[pu] Deg(c)[deg] Pd(a)[kW] Qd(a)[kVAr] Pd(b)[kW] Qd(b)[kVAr] Pd(c)[kW] Qd(c)[kVAr] Vmin[pu] Vmax[pu] VnomNominal voltage of the load model in per-unit. Type 0 - Slack1 - PQ2 - PV ZIP Load Model The parameters Z, I, and P represent the relative participation of each component in the ZIP load model. For a constant power load (PQ model): Z = 0I = 0P = 1 Any combination is allowed provided that: Z + I + P = 1 Connection 0 - Y (Wye)1 - D (Delta) Phases The phases field indicates the phases where the loads are connected. 100 - A010 - B001 - C110 - AB011 - BC101 - AC111 - ABC DATA_BRANCH.DAD This file describes all branch elements of the system, including lines, transformers, shunt elements, voltage regulators, and switches. nBranchID Area phases bus_from bus_to Type ampacity(A) ampacity(B) ampacity(C) raa xaa rba xba rbb xbb rca xca rcb xcb rcc xcc yaa yba ybb yca ycb ycc NOTE:All impedance parameters Zabc must be inserted in Ohms. NOTE 2:All shunt admittance values Yshunt must be inserted in µS (microSiemens). Type 0 - Line1 - Transformer2 - Shunt Element3 - Voltage Regulator4 - Switch Phases 100 - A010 - B001 - C110 - AB011 - BC101 - AC111 - ABC DATA_TRANSFORMER.DAD This file contains transformer data. nTransformerID branch_id area_prim area_sec connection bus_from bus_to Snom[kVA] R[pu] X[pu] Vprim[kV] Vsec[kV] a b NOTE:Voltages must be inserted as line-to-line values. NOTE 2:The parameters a and b represent tap deviations from nominal voltage at the primary and secondary sides, respectively. Transformer Connection Types 0 - Ygr - Ygr1 - Ygr - Y2 - Ygr - D3 - Y - Y4 - Y - Ygr5 - Y - D6 - D - Ygr7 - D - Ygr8 - D - D DATA_SWITCH.DAD Switch status in the network. ID bus_id status DATA_GENERATOR.DAD Generator data used in the simulations. nGeneratorsID Bus Vset[pu] Pga[kW] Qga[kVAr] Pgb[kW] Qgb[kVAr] Pgc[kW] Qgc[kVAr] Pmin[kW] Pmax[kW] Qmin[kVAr] Qmax[kVAr] DATA_AREAS.DAD System base values. nBasesID Sbase[MVA] Vbase[kV] NOTE Sbase must be inserted in MVAVbase must be inserted in kV

提供机构:
Zenodo
创建时间:
2026-03-10
二维码
社区交流群
二维码
科研交流群
商业服务