five

Precast Concrete Wall Tests - Grouted metal duct connections

收藏
DataCite Commons2025-06-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/designsafe.storage.published/PRJ-2575/#detail-7633032512614896106-242ac116-0001-012
下载链接
链接失效反馈
官方服务:
资源简介:
During the 2010/2011 Canterbury (New Zealand) earthquakes damage was observed to grouted connections used for precast concrete wall panels. A series of experimental tests were subsequently performed to investigate the in-plane seismic behaviour of precast concrete walls with grouted connections. Testing comprised of nine reversed cyclic in-plane tests of full-scale precast concrete wall panels. Seven walls used grouted metal duct connections at the wall-to-foundation joint, with test variables considering panel geometry, axial load, and panel reinforcement. An additional two walls were tested with grouted sleeve wall-to-foundation connections with both a single and double layer of panel reinforcement. Test data from these nine precast wall tests is published including wall design, test setup and procedures, clean sensor data, and photos.