CCS - CCS8 Mooring data May 2019 deployment
收藏DataCite Commons2020-07-30 更新2025-04-09 收录
下载链接:
https://data.csiro.au/collections/#collection/CIcsiro:42879v1/DItrue
下载链接
链接失效反馈官方服务:
资源简介:
Project Overview: A range of solutions will be required to reach globally agreed emissions reductions targets for carbon dioxide (CO2). Carbon capture and storage (CCS) is part of the suite of technologies that will contribute to lowering atmospheric emissions of CO2 from Australia's energy system. There are a wide variety of technologies at various stages of technical and commercial readiness, with more development underway for cost effective CO2 capture and storage. Our research will provide new knowledge to inform cost-efficient measurement, monitoring and verification (MMV) of the environment of CCS projects in coastal waters. --o-- Description: Relevant component details: make, model, serial number, firmware version, settings: Sensor | Make | Model | Serial Number | Calibration fCO2 sensor | Battelle | MApCO2 | 203 | Pre and post deployment calibration; Continuous (see below). pH, DO,T and S sensor | Seabird Seaphox | SeaFET | 1001 | 2017-05, factory calibrated, verified by CSIRO lab pH, DO,T and S sensor | Seabird Seaphox | SBE-37-SMP-ODO | 15560 | 2017-05, factory calibrated, verified by CSIRO lab pH, DO,T and S sensor | Seabird Seaphox | SBE-63 | 1690 | 2017-05, factory calibrated, verified by CSIRO lab Calibration Information (if applicable) Battelle: The LI-COR 820 in the Battelle pco2 sensor response is checked before and after each deployment using a range of CO2-in-air reference gases (0, 260, 370, 450 micromol/mol) at CSIRO, Hobart. The sensor measurement using factory calibrations for the LI-CO2 820 is typically within 1 micromol/mol of the reference gas value. If the LI-COR 820 measurements and the CO2-in-air reference gas values are different by more than 2 micromol/mol, a correction is applied to Li-CO2 820 output based the reference gas values. A seawater bath operated over a range of temperatures and CO2 expected in the field is then used to check the MapCO2 system (equilibrator and LI-COR 820 measurement) against a General Oceanics 8050 CO2 sensor to ensure the systems agree within 2 micromol/mol. Pressure measurements are made using the LI-COR 820 pressure sensor, checked against a Druck DPI142 pressure indicator and verified to agree within 0.5 kPa before and after each deployment. Seaphox: SBE 37 (T, S, DO) and the SeaFET (pH) are calibrated by the factory and verified in the CSIRO laboratory. The pH reported in the files is flagged questionable for the pre-deployment calibrated data due to possible calibration changes which can occur after deployment pH (calibrated) is further processed after the recovery using in situ bottle sample where available, using Total Alkalinity (TA) and Dissolved Inorganic Carbon (DIC), which will be converted to pH using CO2SYS, where the Lueker k1k2 dissociation constant is used. Location: 38.2564S 147.4162E
提供机构:
CSIRO
创建时间:
2020-02-04



