Effect of sparger on injection cooling performance of cryogenic liquids.
收藏DataCite Commons2020-07-29 更新2025-04-16 收录
下载链接:
http://iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0025800&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Injection cooling is used for short term storage of cryogenic liquids by injection of a gas through the liquid. This causes liquid subcooling that reduces the boil off loss of liquid. Among various factors, sparger design (type, diameter of hole and number of holes) plays a significant role as it dictates the bubble dynamics in the liquid tank and thus the gas-liquid heat and mass transfer. This is the first work, to the best knowledge of the authors, on the sparger design in terms of the hole diameter and number of holes, on the cooling performance of such a system. Four types of sparger (single orifice, ring/spider, perforated plate and porous plate sparger) available commercially have been considered. A mathematical model of injection cooling based on lumped
parameter approach has been developed and simulation was carried out to determine the effect of sparger design. Liquid subcooling was obtained for all the four types of spargers. It was observed that the rate of cooling increases with the decrease in sparger hole diameter. However, the effect of number of holes on liquid subcooling was found to be negligibly small.
提供机构:
International Institute of Refrigeration (IIR)
创建时间:
2019-07-04