Experimental dataset: stationary images for digital image correlation uncertainty quantification
收藏NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://zenodo.org/record/13375615
下载链接
链接失效反馈官方服务:
资源简介:
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------- SUMMARY ---------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
Stereo-DIC 5 MPx system was used to capture sets of stationary images for quantification of DIC uncertainties.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
-------------------------------------------------------------------------------- FOLDERS ---------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
Image sets:
Set 1: 100 stationary images with cross polarisation to reduce effect of specular reflection. Test sample clamped in the clamps of a uniaxial tensile test bench.
Set 2: Same as set 1, but test sample unclamped at the bottom, displaced by 1 mm vertically. Meant to introduce rigid body motion into teh stationary images.
For investigation of the impact of cross-polarisation: image gradients made similar as much as possible by adjusting exposure time and apetrture.
Set 3: With cross polarisation - 100 stationary images.
Set 4: Without cross polarisation - 100 stationary images.
Images for stereo calibration:
Calib_sets_1_2: Calibration images for sets 1 and 2 mentioned above
Calib_sets_3: Calibration images for set 3 mentioned above
Calib_sets_4: Calibration images for set 4 mentioned above
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
------------------------------------------------------------------------ SUPPORTING NINFORMATION --------------------------------------------------------------------
----------------------------------------------------------------------------------------------------------------------------------------------------------------------
Image folder for each set contains an *.xaml file with image capture settings.
Each calibration image folder contains a *.caldat file with intrinsic and extrinsic stereo camera parameters identified by MatchID 2024.2 DIC package.
创建时间:
2024-08-26



