遇见数据集

Experimental dataset: stationary images for digital image correlation uncertainty quantification

收藏
NIAID Data Ecosystem2026-05-02 收录
数据链接:
官方服务:

资源简介:

---------------------------------------------------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------- SUMMARY --------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- Stereo-DIC 5 MPx system was used to capture sets of stationary images for quantification of DIC uncertainties. ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- -------------------------------------------------------------------------------- FOLDERS --------------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- Image sets: Set 1: 100 stationary images with cross polarisation to reduce effect of specular reflection. Test sample clamped in the clamps of a uniaxial tensile test bench. Set 2: Same as set 1, but test sample unclamped at the bottom, displaced by 1 mm vertically. Meant to introduce rigid body motion into teh stationary images. For investigation of the impact of cross-polarisation: image gradients made similar as much as possible by adjusting exposure time and apetrture. Set 3: With cross polarisation - 100 stationary images. Set 4: Without cross polarisation - 100 stationary images. Images for stereo calibration: Calib_sets_1_2: Calibration images for sets 1 and 2 mentioned above Calib_sets_3: Calibration images for set 3 mentioned above Calib_sets_4: Calibration images for set 4 mentioned above ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------ SUPPORTING NINFORMATION -------------------------------------------------------------------- ---------------------------------------------------------------------------------------------------------------------------------------------------------------------- Image folder for each set contains an *.xaml file with image capture settings. Each calibration image folder contains a *.caldat file with intrinsic and extrinsic stereo camera parameters identified by MatchID 2024.2 DIC package.

创建时间:
2024-08-26
二维码
社区交流群
二维码
科研交流群
商业服务