five

Two-wire communication channel with anomalies

收藏
IEEE2026-04-17 收录
下载链接:
https://ieee-dataport.org/documents/two-wire-communication-channel-anomalies
下载链接
链接失效反馈
官方服务:
资源简介:
A dataset related to a cable under anomalies conditions while a transmitter (AWG) sends a binary PAM signal to a receiver. The signals are acquired by an oscilloscope. The anomalies were manually forced on the cable under test: air-exposed, water-exposed conductors, and tapping. In the dataset, the signals are also available for normal cable.In particular, for the air-exposed conductor, the insulators were removed for both wires for a length of 5 cm to 50 cm with a step of 5 cm, and then a distance of 0.5 cm was kept between the two exposed wires to avoid short circuits. In the case of a water-exposed conductor, the cables were placed inside a water container that completely covered them once the insulation was removed. The anomaly lengths are chosen as for the air-exposed conductors. Another two-wire cable was soldered at half the wireline length for the tapping. The branch length was varied from 3 m to 15 m with a step of 3 m.A number of 10000 records were acquired with the oscilloscope by considering a time window of 5.6 µs for each considered anomaly and in the case of a normal cable. For each record, a different PRBS was set by the AWG. In the case of air/water-exposed conductors, 1000 acquisitions were performed for each anomaly length, while for the tapping, they were 2000.The experimental setup consists of the AWG 420 by Tektronix, which provides the binary PAM signal at the symbol rate of 125 MHz and with an amplitude of 0.5 V according to a PRBS of 1024 bytes. The signal is acquired by the oscilloscope MSO64B by Tektronix at a sampling frequency of 6.25 GSa/s, with a configured input impedance of 50 Ω and a bandwidth of 4 GHz. The oscilloscope works in high-resolution mode, thus exhibiting a resolution of 13 bits. The cable under test was a CAT 5E 4PR type and was placed around a circular structure with a radius of 55 cm and then connected to the oscilloscope input.Additional information is available on the paper:E. Balestrieri, P. Daponte, L. De Vito, F. Picariello, S. Rapuano, and I. Tudosa, Passive Measurement Method for Anomalies Diagnosis and Classification of Two-wire Communication Channels using Machine Learning submitted to IEEE Transactions on Instrumentation and Measurement.
提供机构:
Picariello, Francesco
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作