five

Data from: Collaborative Guarded-Hot-Plate Tests between the National Institute of Standards and Technology and the National Physical Laboratory

收藏
DataCite Commons2020-10-23 更新2025-04-16 收录
下载链接:
https://data.nist.gov/od/id/mds2-2106
下载链接
链接失效反馈
官方服务:
资源简介:
A bilateral study to compare guarded-hot-plate measurements at extended temperatures between laboratories at the National Institute of Standards and Technology (NIST) and the National Physical Laboratory (NPL) is presented. Measurements were conducted in accordance with standardized test methods (ISO 8302 or ASTM C177) over a temperature range from 20 °C to 160 °C (293 K to 433 K). Following a blind round-robin format, specimens of non-woven fibrous glass mat, approximately 22 mm thick and having a nominal bulk density of 200 kg/m3, were prepared and studied. Results of the study show that the thermal conductivity measurements agree over the temperature range of interest to within ±1.0 %, or less.
提供机构:
National Institute of Standards and Technology
创建时间:
2019-12-31
二维码
社区交流群
二维码
科研交流群
商业服务