Evaluation of in vitro experimental model for analysis of bioceramic sealers
收藏Figshare2022-10-01 更新2026-04-28 收录
下载链接:
https://figshare.com/articles/dataset/Evaluation_of_in_vitro_experimental_model_for_analysis_of_bioceramic_sealers/21310432
下载链接
链接失效反馈官方服务:
资源简介:
Abstract This study aimed to evaluate physicochemical properties of three ready-to-use calcium silicate-based endodontic sealers: Endosequence BC Sealer, Bio C Sealer, and Sealer Plus BC. Radiopacity was evaluated using specimens of 10 mm in diameter and 1 mm in height, along with an aluminum step wedge. For the flow test, 0.5 mL of each sealer was deposited between glass plates and the mean of the measurement of two diameters was considered the cement flow value. For pH and calcium release, root canals of 30 prototypes of upper incisor acrylic resin teeth were filled with sealer and gutta percha point and then immersed in containers with 13 mL of ultrapure water. Both pH and release of calcium ions (atomic absorption spectrophotometer) were measured at 3, 24, 72, and 168 h. Acrylic resin teeth were scanned by Micro-CT 1174 at the time of pH and calcium ion readings for volumetric change analysis. The data were analyzed by ANOVA, Tukey’s, Kruskal-Wallis, and Dunn’s tests. Endosequence BC Sealer presented the lowest, and Bio C Sealer the highest volumetric change after 72 h and 168 h (p
创建时间:
2022-10-01