遇见数据集

Mimicking Cochlear Pre-Processing using Critically Coupled MEMS Sensors

收藏
Zenodo2025-11-15 更新2026-05-26 收录
官方服务:

资源简介:

Measurement Data of Two Coupled MEMS Resonators Used as Acoustic Sensors This dataset contains experimental measurement data from two coupled MEMS resonators used as an acoustic sensor.The data are organized into six zipped folders, each corresponding to a specific measurement analysis. Unless stated otherwise: MEMS time-series files are stored in .mat format. Sampling frequency of MEMS measurements: 125 kHz. In every .mat file: Row 1 = resonator with higher listed frequency Row 2 = resonator with lower listed frequency 1. Sensitivity_analysis_measurements.zip Subfolder (I): 3630_3790_Hz_sweep_high_resolution_recheck_2/ Time-series measurements of two coupled resonators with natural frequencies 3790 Hz and 3630 Hz. Sampling frequency: 125 kHz Response to a 1–10 kHz acoustic sweep Filename example:Cantilever_3790_Hz_3630_Hz_DC_0xfffff667_cf_0.5_excitation_0.01.mat Parameter meaning: 3790_Hz → Resonator 1 (row 1) 3630_Hz → Resonator 2 (row 2) DC_0xfffff667 → DC = −150 mV (2’s complement, hexadecimal) cf → coupling strength excitation → signal-generator driving voltage Subfolder (II): Input_sound_sweep_1k_10kHz_2/ Microphone recordings of the loudspeaker sweeps. Sampling frequency: 44 kHz Files stored as .wav Example:Old_speaker_amplitude_frequency_1000-10000Hz0.01.wav Notes: Sweep range: 1–10 kHz Driving amplitude: e.g., 0.01 V Convert voltage to sound pressure (Pa) by: Sound pressure (Pa) = voltage_from_wav / 0.0149 Included MATLAB code File: Sensitivity_determining_plot_code.m Computes peak-to-peak amplitudes of MEMS responses Converts microphone recordings into pressure Computes sensitivity (V/Pa) Plots sensitivity vs. coupling strength and input amplitude Uses the relation: gamma_12 * gamma_21 = (cf / 2)^2 due to FPGA buffer-board scaling and symmetric coupling. ➡️ Run the script directly to reproduce sensitivity plots. 2. Frequency_tunability_analysis_measurements.zip Subfolder: Sweep_near_bifurcation_Negative_to_positive_af/ Time-series responses to a 3–4.5 kHz acoustic sweep with varying feedback and coupling parameters. Example filename:Cantilever_3790_Hz_3630_Hz_DC_0xfffff667_af1_-0.5_af2_-0.5_cf_1.375.mat Parameter meaning: af1 → feedback strength of resonator 1 af2 → feedback strength of resonator 2 cf → coupling strength Included MATLAB code File: Frequency_analysis_3D_plot_code.m Computes FFT for all (af1, af2, cf) combinations Extracts resonance frequencies from FFT maxima Generates 3D colormap plots of resonance vs. feedback Also plots effective coupling vs feedback Values in plots are halved due to the FPGA buffer board. ➡️ Run the script to reproduce resonance-frequency maps. 3. Frequency_tunable_Regime_1_DC_vs_C_crit.zip Measurements in Regime 1 (frequency-tunable), no sound excitation. Example filename:Cantilever_3630_Hz_3790_Hz_DC_100mV_Cf_0.5.mat Includes measurements for varying: DC offset Coupling strength (Cf) Included MATLAB code File: Amplitude_vs_Cf_different_DC_3630Hz_3790Hz.m Plots amplitude vs. coupling strength for several DC values The critical coupling CcritC_{\text{crit}}Ccrit is defined as the value of Cf where the amplitude exceeds 100 mV ➡️ Run the script to extract amplitude vs Cf for different DC values. 4. Frequency_tunable_Regime_2_DC_vs_C_crit.zip Same structure as Regime 1, but corresponding to Regime 2 (another frequency-tunable region). Included MATLAB scripts Run the script corresponding to each resonance pair: Amplitude_vs_Cf_different_DC_3630Hz_3730Hz.m Amplitude_vs_Cf_different_DC_3630Hz_3790Hz.m Amplitude_vs_Cf_different_DC_3790Hz_3730Hz.m ➡️ Run the script to extract amplitude vs Cf for different DC values. 5. Frequency_untunable_Regime_DC_vs_C_crit.zip Measurements from the frequency-untunable regime, with varying DC and coupling strength. Included MATLAB scripts Amplitude_vs_Cf_different_DC_3630Hz_4380Hz.m Amplitude_vs_Cf_different_DC_5190Hz_3630Hz.m Amplitude_vs_Cf_different_DC_5190Hz_4380Hz.m ➡️ Run the script to extract amplitude vs Cf for different DC values. 6. Frequency_response_different_regimes_before_bifurcation.zip Contains .fig files showing frequency responses of the coupled resonators just before Hopf bifurcation in: Frequency-untunable regime Frequency-tunable regime 1 Frequency-tunable regime 2 These figures illustrate how the system behaves in the non-linear regime near the bifurcation point.

提供机构:
Zenodo
创建时间:
2025-11-15
二维码
社区交流群
二维码
科研交流群
商业服务