five

Behaviour of dissolved inorganic salts in the cooling water of a nuclear power plant open recirculation system and formation of water discharge

收藏
DataONE2024-06-17 更新2024-06-22 收录
下载链接:
https://search.dataone.org/view/sha256:c19b61d5f690c7d3c64d06d1bed17b018a5ccf22ead2c9024efb1b4777159600
下载链接
链接失效反馈
官方服务:
资源简介:
The main problem in the operation of nuclear power plants is the scale formation of mineral impurities in an open recirculating system. However, water discharge from an open recirculating system into water bodies can lead to changes in the chemical equilibrium of wastewater components and requires constant monitoring. The purpose of this study was to analyse the behaviour of dissolved inorganic salts in water in an open recirculating system during water treatment using the example of the Rivne Nuclear Power Plant. Moreover, the analysis impact of their discharge with return water in the Styr River. The dissolved inorganic salt concentration has a significant impact on the efficiency of the system and the environment of an open recirculating system power plant. Altogether, each dissolved inorganic salt component was analysed separately using standard measurement methods, using statistical methods of data processing, and correlation analysis. In addition, the annual discharge of the disso..., Measurements were performed for the nuclear power plant ORS process and return water and water of the Styr River in the RNPP discharge area using standard methods. Water pH was measured by potentiometric method with a multi-meter І-160. Ca2+, Mg2+, and TH were measured by ethylenediaminetetraacetic acid complexometric titration. Flame photometry has been used for measuring the concentration of Na+, K+, and silver nitrate titrate has been used for measuring the concentration of Cl-. Method of barium sulfate turbidity has been used for measuring the concentration of SO42-. TDS was measured using the gravimeter method. TA, and ΣHCO3-, CO32- – were measured by titration method. The ORS RNPP is designed for operation at COC ranging from 1.5 to 7.0. The DIS discharge (D, t) for each component was calculated using the formula D = C · F / 1000000 (where: C – is the concentration components of DIS in the return cooling water, mg/dm3; F – is the amount of return cooling water, m3). The statistica..., , # Behaviour of dissolved inorganic salts in the cooling water of a nuclear power plant open recirculation system and formation of water discharge [https://doi.org/10.5061/dryad.5tb2rbpc7](https://doi.org/10.5061/dryad.5tb2rbpc7) This dataset contents involved measuring the concentration of DIS: anions HCO3-, CO32-, SO42-, Cl- and cations Ca2+, Mg2+, Na+, and their total parameters of contents total dissolved solids (TDS), total alkalinity (TA), total hardness (TH), and hydrogen pH value. The dissolved inorganic salt concentration has a significant impact on the efficiency of the system and the environment of an open recirculating system power plant. Altogether, each dissolved inorganic salt component was analysed separately using standard measurement methods, using statistical methods of data processing, and correlation analysis. In addition, the annual discharge of the dissolved inorganic salts components was calculated and the amount of discharge was assessed for compliance with the...
创建时间:
2025-08-01
二维码
社区交流群
二维码
科研交流群
商业服务