five

Raw data.

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://figshare.com/articles/dataset/Raw_data_/28947786
下载链接
链接失效反馈
官方服务:
资源简介:
Background Malaria during pregnancy is a common public health problem in sub-Saharan Africa. It poses a double burden as it affects the health of mothers, their fetuses and neonates. Moreover, due to malaria parasites sequestration in the placenta, microscopy might miss infections. Hence, rapid diagnostic tests (RDTs) are good alternatives for diagnosing malaria in pregnancy even at health facilities or periphery or lower-level healthcare facilities (e.g., health posts). However, performance of RDTs should be closely monitored as their sensitivity and specificity are affected by many factors. Methods A health facility-based cross-sectional study was conducted among 302 pregnant women with suspected malaria infection to evaluate the performance of the newly introduced BIOCREDIT Pf/Pv plasmodial lactate dehydrogenase (pLDH) RDT. Venous blood samples were collected from all eligible pregnant women and tested for Plasmodium infection using BIOCREDIT Pf/Pv and CareStart™ Pf/Pv RDTs, microscopy and polymerase chain reaction (PCR) following standard protocols. The performance of BIOCREDIT Pf/Pv was evaluated using the following parameters: sensitivity, specificity, positive and negative predictive values and kappa-value. These parameters were calculated using online SISA software. Results Of the 302 pregnant women with complete data, 166 (55.0%), 180 (59.6%), 191 (63.2%) and 207 (68.5%) tested positive by CareStart™ Pf/Pv, BIOCREDIT Pf/Pv, microscopy and PCR, respectively. The sensitivity of BIOCREDIT Pf/Pv in detecting P. falciparum was 89.4%, 75.4% and 55.6% as compared to CareStart™ Pf/Pv, microscopy and PCR tests, respectively, while the sensitivity for P. vivax was 81.8%, 84.3% and 86.7%, respectively. The specificity of BIOCREDIT Pf/Pv was > 90% when compared to all the three diagnostic tests. When considering PCR as a reference test, BIOCREDIT Pf/Pv was more sensitive (55.6%) than CareStart™ Pf/Pv (37.6%) for detecting P. falciparum but had similar sensitivity (86.7%) in detecting P. vivax. Conclusions BIOCREDIT Pf/Pv performed better for the diagnosis of P. falciparum infection in pregnant women than the previously in-use CareStart™ Pf/Pv. We recommend using the BIOCREDIT Pf/Pv RDT in Ethiopia for the diagnosis of both species given the high prevalence and widespread nature of the hrp2/3 gene deletion in the country.
创建时间:
2025-05-07
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作