five

Simulated brainweb PET/MR data sets for denoising and deblurring

收藏
NIAID Data Ecosystem2026-05-01 收录
下载链接:
https://zenodo.org/record/4897349
下载链接
链接失效反馈
官方服务:
资源简介:
The data set consists of 20 subjects based on the normal anatomical models from the brainweb phantom. https://brainweb.bic.mni.mcgill.ca/ For each subject the data is organized as follows: subjectXX mu.nii.gz -> (attenuation image) t1.nii.gz -> (high resolution and low noise T1 MR) sim_0 -> first simulated PET acquisition true_pet.nii.gz -> true tracer uptated osem_psf_counts_0.0E+00.nii.gz -> OSEM recon of simulated noise free data osem_psf_counts_1.0E+07.nii.gz -> OSEM recon of simulated noisy data (1e7 counts) -> high noise level osem_psf_counts_5.0E+08.nii.gz -> OSEM recon of simulated noisy data (5e8 counts) -> low noise level sim_1 -> second simulated PET acquisition osem_psf_counts_0.0E+00.nii.gz osem_psf_counts_1.0E+07.nii.gz osem_psf_counts_5.0E+08.nii.gz true_pet.nii.gz sim_2 -> third simulated PET acquisition osem_psf_counts_0.0E+00.nii.gz osem_psf_counts_1.0E+07.nii.gz osem_psf_counts_5.0E+08.nii.gz true_pet.nii.gz All data sets have a shape of (256,256,258) and a voxel size of 1mm x 1mm x 1mm and are provided in nifti format. All PET acquisitions have different contrasts. PET data was simulated with a projector that approximates the geometry and resolution of the Siemens Biograph mMR. The T1 MR scans and antomical models used to create the ground truth PET images are taken from the BrainWeb: Simulated Brain Database. See: http://www.bic.mni.mcgill.ca/brainweb/ C.A. Cocosco, V. Kollokian, R.K.-S. Kwan, A.C. Evans : "BrainWeb: Online Interface to a 3D MRI Simulated Brain Database" NeuroImage, vol.5, no.4, part 2/4, S425, 1997 -- Proceedings of 3-rd International Conference on Functional Mapping of the Human Brain, Copenhagen, May 1997. R.K.-S. Kwan, A.C. Evans, G.B. Pike : "MRI simulation-based evaluation of image-processing and classification methods" IEEE Transactions on Medical Imaging. 18(11):1085-97, Nov 1999. R.K.-S. Kwan, A.C. Evans, G.B. Pike : "An Extensible MRI Simulator for Post-Processing Evaluation" Visualization in Biomedical Computing (VBC'96). Lecture Notes in Computer Science, vol. 1131. Springer-Verlag, 1996. 135-140. D.L. Collins, A.P. Zijdenbos, V. Kollokian, J.G. Sled, N.J. Kabani, C.J. Holmes, A.C. Evans : "Design and Construction of a Realistic Digital Brain Phantom" IEEE Transactions on Medical Imaging, vol.17, No.3, p.463--468, June 1998
创建时间:
2023-06-22
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作