five

GRANTA-519 Nanopore sequencing

收藏
NIAID Data Ecosystem2026-05-02 收录
下载链接:
https://www.ncbi.nlm.nih.gov/sra/ERP172790
下载链接
链接失效反馈
官方服务:
资源简介:
Cell-line derived data from published study: Hansen MH, Cédile O, Kjeldsen MLG, Thomassen M, Preiss B, von Neuhoff N, Abildgaard N, Nyvold CG. Toward Cytogenomics: Technical Assessment of Long-Read Nanopore Whole-Genome Sequencing for Detecting Large Chromosomal Alterations in Mantle Cell Lymphoma. J Mol Diagn. 2023 Nov;25(11):796-805. doi: 10.1016/j.jmoldx.2023.08.004. Epub 2023 Sep 7. PMID: 37683892. Base calling: Dorado, Super-accurracy basecalling, using NVIDIA Tesla V100 graphics card Background The current advances and success of next-generation sequencing hold the potential for the transition of cancer cytogenetics toward comprehensive cytogenomics. However, the conventional use of short reads impedes the resolution of chromosomal aberrations. Thus, this study evaluated the detection and reproducibility of extensive copy number alterations and chromosomal translocations using long-read Oxford Nanopore Technologies whole-genome sequencing compared with short-read Illumina sequencing. Using the mantle cell lymphoma cell line Granta-519, almost 99% copy-number reproducibility at the 100-kilobase resolution between replicates was demonstrated, with 98% concordance to Illumina. Collectively, the performance of copy number calling from 1.5 million to 7.5 million long reads was comparable to 1 billion Illumina-based reads (50× coverage). Expectedly, the long-read resolution of canonical translocation t(11;14)(q13;q32) was superior, with a sequence similarity of 89% to the already published CCND1/IGH junction (9× coverage), spanning up to 69 kilobases. The cytogenetic profile of Granta-519 was in general agreement with the literature and karyotype, although several differences remained unresolved. In conclusion, contemporary long-read sequencing is primed for future cytogenomics or sequencing-guided cytogenetics. The combined strength of long- and short-read sequencing is apparent, where the high-precision junctional mapping complements and splits paired-end reads. The potential is emphasized by the flexible single-sample genomic data acquisition of Oxford Nanopore Technologies with the high resolution of allelic imbalances using Illumina short-read sequencing. Please cite paper, if raw data is used in a research project. Main contact: Marcus H. Hansen, marcus.hoy.hansen[at]rsyd.dk
创建时间:
2025-05-23
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作