five

Baseline and Endpoint auditory tests (ABR and DPOAE): Macrophage ablation followed by partial repopulation protected against cisplatin-induced hearing loss and OHC dysfunction (Experiment 1) (Manuscript: Fig. 2; Fig. S2-1, Fig. S2-2_Supp Fig 5-3)

收藏
Figshare2024-02-24 更新2026-04-08 收录
下载链接:
https://figshare.com/articles/dataset/Baseline_and_Endpoint_auditory_tests_ABR_and_DPOAE_Macrophage_ablation_followed_by_partial_repopulation_protected_against_cisplatin-induced_hearing_loss_and_OHC_dysfunction_Experiment_1_Manuscript_Fig_2_Fig_S2-1_Fig_S2-2_Supp_Fig_5-3_/25001771/1
下载链接
链接失效反馈
官方服务:
资源简介:
Prior to the start of PLX3397 chow pre-treatment and at the end of the cisplatin administration protocol, mice underwent two types of auditory tests: auditory brainstem responses (ABRs; measure hearing sensitivity) and distortion product otoacoustic emissions (DPOAEs; indirectly measure outer hair cell function). These data suggest that partial macrophage ablation protected against cisplatin-induced hearing loss and OHC dysfunction (Experiment 1).For <b>ABR</b> measurements, subcutaneous needle electrodes (Rhythmlink, Columbia, SC, USA) were placed behind left pinna of the test ear (reference), vertex (active), and near the tail of the mouse (ground). Tone-burst stimuli (Cos2, 3 msec, 0.5 msec rise/fall in alternating polarity) were presented at a rate of 29.9/sec<b> </b>at 8, 11.2, 16, 22.4, 32, and 40 kHz starting at 90dB SPL. At each sound level, 1024 waveforms were averaged, amplified (20x), and filtered (HP: 300Hz, LP: 3kHz, NT: 60Hz). At near-threshold sound pressure levels (SPL), the ABR waveforms were recorded twice, and two waveforms were superimposed for comparison. ABR threshold was defined as the lowest stimulus intensity that resulted in a reproducible waveform displaying identifiable peaks.<b>DPOAEs</b> were measured in response to two primary pure tones, f1 and f2, generated by Multi Field 1 speakers. Two primary tones were presented at 6 frequency pairs, where f2 corresponded to ABR test frequencies (f2 = 8, 11.2, 16, 22.4, 32, 40kHz; f2/f1 = 1.25). The sound level was increased in 5dB steps from 30dB to 90dB. At each sound level, 512 responses were averaged. DPOAE at 2f1-f2 was recorded in the mouse inner ear canal using an ER-10B+ microphone (Etymotic, Elk Grove Village, IL, USA) connected to a modified pipette tip to fit the mouse external ear canal. Biological noise floors and amplitudes were calculated for each treatment group and plotted relative to each other.
提供机构:
Hu, Xuzhen; Fernandez, Katharine; Lee, John; Yuen, Peter; Hayase, Naoki; Cunningham, Lisa L.; Sung, Cathy; Warchol, Mark; Star, Robert; Cheng, Hui
创建时间:
2024-02-24
二维码
社区交流群
二维码
科研交流群
商业服务