A New Analog Integrator for Magnetic Diagnostics on EAST
收藏科学数据银行2022-11-27 更新2026-04-23 收录
下载链接:
https://www.scidb.cn/detail?dataSetId=2c3e0128cbee43a78bb11c47de80b553
下载链接
链接失效反馈官方服务:
资源简介:
A new kind of analog integrator has been developed for Magnetic diagnostics (MDs) on Experimental Advanced Superconducting Tokamak (EAST). While previous analog integrators are single-ended input, which has low common mode rejection ration (CMRR), a kind of difference integrator is introduced which has the same structure as the standard difference amplifier. The linear drift compensation method is used for determining the effective drift slope, then the plasma control system (PCS) use the drift slope to rectify the integration signal in real time. To improve the maintainability and testability of the integrator system, a new integrator controller was developed, which uses an ARM micro-controller and the lightweight IP protocol stack to realize the network control. The tests show that the upgraded integrator works well, its CMRR is high up to 125 dB when the common voltage is 1.5 V, and the processed integration drift is about 200 uVs /1000 s, which is much better than the previous integrator.
提供机构:
王枫; 王勇
创建时间:
2022-10-28