Performance simulation of a heat pump drying system using r744 as refrigerant.
收藏DataCite Commons2020-09-18 更新2025-04-16 收录
下载链接:
http://www.iifiir.org/clientBookline/service/reference.asp?INSTANCE=EXPLOITATION&OUTPUT=PORTAL&DOCID=IFD_REFDOC_0019096&DOCBASE=IFD_REFDOC_EN&SETLANGUAGE=EN
下载链接
链接失效反馈官方服务:
资源简介:
Drying is an energy intensive thermal process. The specific energy consumption in industrial systems is normally higher than 0.8 kWh/kg of evaporated water and the thermal energy demand in most drying systems is provided through burning of fossil fuels. The potential of using R744 (CO2) as working media in a heat pump drier was investigated for a drying process at 45°C, 60°C and 70°C. The trans-critical temperature glide of CO2 reduces the large temperature differences during re-heating of the drying air. The obtained Coefficients of Performance were between 3.4 and 4.3 resulting in specific energy consumption in the range of 0.24 to 0.27 kWh/kg of evaporated water for the different drying processes. The simulations confirm that heat pump assisted drying has the potential to reduce the energy demand by around 70% in general and shows the feasibility of applying heat pump drying also at drying conditions up to 70°C.
提供机构:
International Institute of Refrigeration (IIR)
创建时间: