five

Data set for a validated open-source multi-solver fourth generation composite femur model

收藏
DataCite Commons2024-09-19 更新2025-04-17 收录
下载链接:
https://researchdata.bath.ac.uk/id/eprint/239
下载链接
链接失效反馈
官方服务:
资源简介:
Contains Abaqus, Ansys and FEBio validated models of fourth generation composite femurs and the output results as well as the experimental data for validation ** The condition for use of these models is that the following publication is cited: ** A.R.MacLeod, H.Rose, H.S.Gill, A Validated Open-Source Multi-Solver Fourth Generation Composite Femur Model, Journal of Biomechanical Engineering, 2016 The files contained in this directory are for the composite femur model F10 discussed in the publication. All models are for the converged 0.75 mm mesh size detailed in the publication. The ABAQUS input file: F10_ABAQUS.inp The ANSYS input file: F10_ANSYS.ans The FEBIO geometry and main input files: F10_FEBIO_GEOM.feb F10_FEBIO_MAIN.feb The predicted equivalent strains for each of the models is given is the 'Results' files: Results_F10_Abaqus.txt Results_F10_Ansys.txt Results_F10_FEBio.txt In these files, rows 1-4 represent strain gauge locations 1-4. There are 11 load increments for each location: 0 to 500 N in 50 N increments. The experimental results are also provided in an identical format: Results_F10_EXPERIMENTAL_STRAINS.txt