Seismic Response of a Shallow Cut and Cover Tunnel in Close Proximity to a Mid-Rise Building
收藏DataCite Commons2020-07-26 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2011-1086.groups/Experiment-3
下载链接
链接失效反馈官方服务:
资源简介:
This test investigated the seismic response of a cut and cover tunnel in close proximity to a mid-rise building (Prototype 12 stories high). Dry Nevada sand with the same relative density (~55%) as the baseline experiments (Experiment 1 & 2) was used.The model is built with a model scale of N = 65. Model structures were built at 1/65th of the prototype dimensions. The model is equipped with sensors throughout including accelerometers, LVDT’s, strain gages, and pressure sensors on the sides of the tunnel. Seven ground motions were applied to the model once 65 g’s was reached in the following order: Northridge, Loma Prieta, Joshua Tree, Chi Chi, Lucerne, Kobe, and Northridge_Strong. These motions were chosen as to provide realistic earthquake motions and a wide range of characteristics. The adjacent mid-rise building was built with a prototype 3-story basement, as is common in tall buildings for parking garages.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2014-08-20