Supplementary Material for: Development of a Bronchoscopy-Radiologic Skills and Task Assessment Tool (BRadSTAT): A Tool for Evaluating the Radiological Skills of Bronchoscopists with Different Experience
收藏DataCite Commons2022-11-25 更新2024-07-29 收录
下载链接:
https://karger.figshare.com/articles/dataset/Supplementary_Material_for_Development_of_a_Bronchoscopy-Radiologic_Skills_and_Task_Assessment_Tool_BRadSTAT_A_Tool_for_Evaluating_the_Radiological_Skills_of_Bronchoscopists_with_Different_Experience/21069313
下载链接
链接失效反馈官方服务:
资源简介:
<b><i>Background:</i></b> Competency using radiologic images for bronchoscopic navigation is presumed during subspecialty training, but no assessments objectively measure combined knowledge of radiologic interpretation and ability to maneuver a bronchoscope into peripheral airways. <b><i>Objectives:</i></b> The objectives of this study were (i) to determine whether the Bronchoscopy-Radiology Skills and Tasks Assessment Tool (BRadSTAT) discriminates between bronchoscopists of various levels of experience and (ii) to improve construct validity using study findings. <b><i>Methods:</i></b> BRadSTAT contains 10 questions that assess chest X-ray and CT scan interpretation using multiple images per question and 2 technical skill assessments. After administration to 33 bronchoscopists (5 Beginners, 9 Intermediates, 10 Experienced, and 9 Experts), discriminative power was strengthened using differential weighting on CT-related questions, producing the BRadSTAT-CT score. Cut points for both scores were determined via cross-validation. <b><i>Results:</i></b> Mean BRadSTAT scores for Beginner, Intermediate, Experienced, and Expert were 74 (±13 SD), 78 (±14), 86 (±9), and 88 (±8), respectively. Statistically significant differences were noted between Expert and Beginner, Expert and Intermediate, and Experienced and Beginner (all <i>p</i> ≤ 0.05). Mean BRadSTAT-CT scores for Beginner, Intermediate, Experienced, and Expert were 63 (±14), 74 (±15), 82 (±13), and 90 (±9), respectively, all statistically significant (<i>p</i> ≤ 0.03). Cut points for BRadSTAT-CT had lower sensitivity but greater specificity and accuracy than for BRadSTAT. <b><i>Conclusion:</i></b> BRadSTAT represents the first validated assessment tool measuring knowledge and skills for bronchoscopic access to peripheral airways, which discriminates between bronchoscopists of various experience levels. Refining BRadSTAT produced the BRadSTAT-CT, which had higher discriminative power. Future studies should focus on their usefulness in competency-based bronchoscopy programs.
提供机构:
Karger Publishers
创建时间:
2022-09-09