Porous Titanium Associated with CaP Coating: In Vivo and In Vitro Osteogenic Performance
收藏Figshare2017-12-01 更新2026-04-29 收录
下载链接:
https://figshare.com/articles/dataset/Porous_Titanium_Associated_with_CaP_Coating_In_Vivo_and_In_Vitro_Osteogenic_Performance/6273476
下载链接
链接失效反馈官方服务:
资源简介:
This in vitro and in vivo study compared different topographies of Ti samples (dense, porosity of 30% and 40%) with or not CaP coating, prepared by powder metallurgy. Osteogenic cells from newborn rat calvaria were plated onto the samples and cell adhesion (24 hours), alkaline phosphatase activity (7 and 10 days) and mineralization nodules (14 days) were assessed. Sixteen rabbits were used for in vivo study. Each animal received three non-treated and three treated implants in the right or left tibia, respectively. Histometric evaluation of bone-implant contact (BIC) were assessed at 1, 2, 4 and 8 weeks. Metallographic analysis revealed porosities of 30% and 40%, with pore size ranging from 250 to 350 µm. Cell adhesion test and ALP revealed similar cell behavior, independently of topography and CaP coating (P > 0.05%). However, CaP coating combined with porosity of 40% influenced positively the mineralized matrix formation (P
创建时间:
2017-12-01