Household appliance-usage preferences, appliance energy consumption and hourly renewable-energy production, per season and date
收藏IEEE2026-04-17 收录
下载链接:
https://ieee-dataport.org/documents/household-appliance-usage-preferences-appliance-energy-consumption-and-hourly-renewable
下载链接
链接失效反馈官方服务:
资源简介:
Twelve (12) realistic datasets encapsulating residents’ preferences, with each dataset representing the appliance-usage preferences expressed for a variant set of households by their respective residents for a specific season and day. The preferences were extracted from the REFIT dataset, a public 500MB dataset which contains real kW readings of the power output for the most energy-intensive shiftable/real-time appliances in 20 households in the UK, between September 2013 and July 2015. The pre-processing performed in order to extract the preferences included (i) converting kW readings per second into perminute readings by removing duplicate records, (ii) converting per-minute readings into hourly readings by summing them up, (iii) defining preference (or not) of an appliance, per hour, through threshold values, and (iv) mapping each household to a resident and assigning the 24-hour preference-batch for a specific date for that household to the corresponding resident. Furthermore, the energy consumption per appliance was derived by examining the kW readings in the original dataset. The datasets that resulted from the above pre-processing can be found in the table below. Each dataset also includes renewable-energy production data, which is uniformly varied based on the number of households and season. A dataset’s hourly peak-production was defined as the output of a 4.5kW PV-system per household, using the standard formula for calculating solar panel energy production:P_PV = Ppeak ∗ (G / Gstandard) − a ∗ (T − Tstandard)subject to (i) solar panels with Ppeak = 450W and a temperature-coefficient a = 0.3, (ii) the Standard Test Conditions and (iii) the average seasonal temperature G3 and irradiance T in the UK:Autumn: G : 9, T : 833Winter: G : 5, T : 750Spring: G : 13, T : 916Summer: G : 17, T : 1000Finally, a renewable-energy production curve is formed from 06:00 to 18:00 by assigning the peak-production value at 12:00 and adjusting the hourly production values according to the standard renewable-energy production curve, as often encountered. THE DATASETS GENERATED BY USING INFORMATION FROM THE REFIT PUBLIC DATASETDatasetDateNum of residents (U)Num of appliances (A)Num of timeslots (T)Households (IDs)Demand (kWh)Available Renewable energy (kWh)Sml_Aut23/10/2013525241 2 3 4 5113.4114Sml_Win11/12/2013525241 3 4 5 696.292Sml_Spg05/04/2014525241 2 3 4 5156.7136Sml_Sum02/06/2014 525241 2 3 4 597.5162Med_Aut29/11/20131049241-10 (2*, 9*)183.6228Med_Win19/01/20141050241 3 4 5 67 8 9 10 13241.0184Med_Spg18/03/2014 1049241-10186.4272Med_Sum15/06/20141047241 2 3 4 517-21156.0324Lrg_Aut23/10/2014 2091241-21 (all)248.9456Lrg_Win25/01/20152091241-21 (all)418.7368Lrg_Spg21/03/20142091241-21 (all)(4*, 11*)340.8544Lrg_Sum28/06/2014 2091241-21 (all)302.1648*date unavailable, closest date retrieved
提供机构:
Papakyriakou, Thalis



