CI-1 RC Perimeter-Frame Column under Near Collapse Loading
收藏DataCite Commons2020-08-19 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2010-0927.groups/Experiment-6
下载链接
链接失效反馈官方服务:
资源简介:
A reinforced concrete column with a rectangular cross section of 36" x 28" and a clear height of 8'-10" was subjected to an axial load equal to 10% of the gross concrete compression capacity followed by a near collapse loading protocol until the lateral resistance of the specimen degraded to 20% or less of the peak resistance exhibited during the test. The test was conducted at the Multi-Axial Subassemblage Testing (MAST) facility at the University of Minnesota-Twin Cities.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2014-04-01