Development and validation of a stability indicating HPLC method to determine diltiazem hydrochloride in tablets and compounded capsules
收藏DataCite Commons2022-06-09 更新2024-07-29 收录
下载链接:
https://scielo.figshare.com/articles/dataset/Development_and_validation_of_a_stability_indicating_HPLC_method_to_determine_diltiazem_hydrochloride_in_tablets_and_compounded_capsules/20039205/1
下载链接
链接失效反馈官方服务:
资源简介:
ABSTRACT A stability indicating HPLC method to determine diltiazem hydrochloride (DTZ) in tablets and compounded capsules was developed and validated according to Brazilian and the International Conference on Harmonization (ICH) guidelines. The separation was carried out on a Purospher Star® C18 (150 x 4.6 mm i.d., 5 µm particle size, Merck Millipore) analytical column. The mobile phase consisted of a 0.05% (v/v) trifluoroacetic acid aqueous solution and a 0.05% trifluoroacetic acid methanolic solution (44:56, v/v). The flow rate was 1.0 mL.min-1 with a run time of 14 minutes. The detection of DTZ and degradation products (DP) was performed at 240 nm, using a diode array detector. The method proved to be linear, precise, accurate, selective, and robust, and was adequate for stability studies and routine quality control analyses of DTZ in tablets and compounded capsules.
提供机构:
SciELO journals
创建时间:
2022-06-09