Special Truss Moment Frame Component Test 8 - 2HSS8x4x1/2
收藏DataCite Commons2020-08-02 更新2025-04-16 收录
下载链接:
https://www.designsafe-ci.org/data/browser/public/nees.public/NEES-2010-0947.groups/Experiment-8
下载链接
链接失效反馈官方服务:
资源简介:
Similarly to 2HSS8x4x1/4 (Component Test 7), 2HSS8x4x1/2 did not exhibit lateral torsional buckling; thus eliminating the need for lateral bracing in beam-type members. Consequently, the plastic rotational capacity and strength degradation rate are mainly governed by the flange local buckling and web local buckling. In order to delay crack propagation across the flanges which proved to cause loss of strength in Specimen 7, cover plates were welded on the flanges of Specimen 8. Due to the combination of smaller b/t and h/t ratios as well as the presence of the cover plates on the flanges of the HSSs, Component Test Specimen 8 exhibited more stable hysteretic behavior than that of Specimen 7. The hysteretic behavior of 2HSS8x4x1/2 shows that the strength only slightly dropped even when the Specimen was pushed to the maximum stroke limit of the actuator (4.92 in. or 9.03% member drift) at the end of the test.
提供机构:
Network for Earthquake Engineering Simulation (NEES)
创建时间:
2014-03-05