Direct mecA Detection from Blood Culture Bottles by Branched-DNA Signal Amplification
收藏PubMed Central2026-05-16 收录
下载链接:
https://pmc.ncbi.nlm.nih.gov/articles/PMC85925/
下载链接
链接失效反馈官方服务:
资源简介:
A branched-DNA (bDNA) signal amplification method was used to detect the mecA gene directly from blood culture broth growing staphylococci. BACTEC blood culture bottles with positive growth indices and containing staphylococcus-like organisms as shown by Gram stain were tested for the presence of the mecA gene. Comparison of test results was done among 225 patients (one blood culture from each patient). Compared with PCR, the sensitivity and specificity of the bDNA method are 100 and 99%, respectively. The bDNA test is carried out in a 96-well format and requires approximately 6 h to perform. Our preliminary results suggest that direct detection of the mecA gene by bDNA signal amplification is (i) sensitive enough to detect mecA directly from blood culture bottles without the requirement for subculture and (ii) as sensitive and specific as the PCR-based method.
提供机构:
American Society for Microbiology (ASM)