five

S1 Dataset -

收藏
NIAID Data Ecosystem2026-05-01 收录
下载链接:
https://figshare.com/articles/dataset/S1_Dataset_-/23196348
下载链接
链接失效反馈
官方服务:
资源简介:
Background Ionizing radiation is being used more frequently in medicine, which has been linked to recognized biological effects such as cancer and mortality. Radiology services are becoming more widely available in Ethiopian health facilities but there is no compiled record of worker’s radiation dose. So, assessing the magnitude and identifying the associated factors of occupational radiation exposure dose among radiology personnel help to design strategies for radiation protection. Objective The study was designed to assess the occupational radiation exposure dose and associated factors among radiology personnel in eastern Amhara, northeast Ethiopia, 2021. Methods Cross-sectional study was conducted from March 25 to April 30, 2021, in 57 health institutions among 198 radiology personnel. The study comprised all eligible radiology personnel. The data were collected using an electronic-based (Google form) self-administered questionnaire, and document review. The data were entered into an excel spread sheet and then, exported to Stata 14 software. Linear regression model was used to analyse the data after checking its assumptions. Variables with a p-value < 0.25 were entered into a multiple linear regression analysis, and those with a p-value < 0.05 were judged significant. VIF was used to check for multi-collinearity. Coefficient of determination was used to check the model fitness. Results The mean (± SD) annual shallow and deep dose equivalents of radiology personnel were 1.20 (± 0.75) and 1.02 (± 0.70) mSv, respectively. Body mass index (β = 0.104, 95% CI: 0.07, 0.14), practice of timing (β = -0.43, 95% CI: -0.73, -0.13), working experience (β = -0.04, 95% CI: -0.048, -0.032), and practice of distancing (β = -0.26, 95% CI: -0.49, -0.17) were found to be statistically significant factors of annual deep dose equivalent. In addition, body mass index (β = 0.113, 95% CI: 0.08, 0.15), practice of timing (β = -0.62 95% CI: -0.93, -0.31) and, working experience (β = -0.044, 95% CI: -0.053, -0.036 had statistically significant associations with annual shallow dose equivalent. Conclusion The annual dose equivalents were two times higher than the global average of annual per caput effective dose due to medical exposure. Body mass index, practice of timing, working experience, and practice of distancing were factors of occupational radiation exposure dose. Strategies focusing on increasing the skill, experience, and lifestyle of radiology personnel would be supreme important means to reduce occupational radiation exposure dose.
创建时间:
2023-05-25
5,000+
优质数据集
54 个
任务类型
进入经典数据集
二维码
社区交流群

面向社区/商业的数据集话题

二维码
科研交流群

面向高校/科研机构的开源数据集话题

数据驱动未来

携手共赢发展

商业合作