WeBaSOOP_Oxidative_Potential_Dithiothreitol_assay_Gradski_park_station_Bor
收藏资源简介:
This dataset is obtained in framework of WeBaSOOP Project. The uploaded .txt document is formatted according to the EBAS submision template. The uploaded .txt file contains metadata with the information regarding start time and end time of the measurements. Originator: Jovasevic-Stojanovic, Milena; Jovanovic, Maja; Petrovic, BojanaAffiliation: Vinča Institute of Nuclear Sciences, VINCA, Mike Petrovic Alasa 12-14, 11351, Belgrade, SerbiaSubmitter: Petrovic, BojanaProject: Horizon Europe project "Research Reinforcing in the Western Balkans in Offline and Online Monitoring and Source Identification of Atmospheric Particles" - WeBaSOOP, GA. 101060170, https://cordis.europa.eu/project/id/101060170 Timezone: UTCStartdate: 2023 03 01 23:00:00Period code: 1 yearResolution code: 2 daysSample duration: 24 hoursStation name: Bor Gradski park Station land use: Urban parkStation setting: Urban and center cityStation latitude: 44.076111Station longitude: 22.099444Station altitude: 378 mComponent: oxidative potential_DTT assayUnit: nmol/min/m3Matrix: pm10Laboratory - sampling: Mining and Metallurgy Institute Bor Instrument type: low_vol_samplerInstrument manufacturer: Mega SystemInstrument model: Lifetek PMSLaboratory - analysis: Vinča Institute of Nuclear SciencesAnalytical measurement technique: spectrophotometricAnalytical instrument name: Lambda35_050Analytical instrument manufacturer: PerkinElmerAnalytical instrument model: Lambda 35Inlet type: Impactor--directInlet description: Upward facing with rain shieldFlow rate: 38.3 l/minFilter face velocity: 44.0 cm/sExposed filter area: 14.5 cm2Filter description: PALLFLEX Tissuequartz 2500QAT-UP 47mmMedium: QuartzFilter conditioning: 293.15 K, 50.0 %RH, 48.0 hSample preparation: Water extractionBlank correction: Blank correctedHumidity/temperature control: NoneHumidity/temperature control description: filter kept at ambient conditions together with sampling headVolume std. temperature: ambientVolume std. pressure: ambientDetection limit expl.: LOD based on 3 x sd of fieldblanksZero/negative values code: Zero/negative impossibleQA1 measure ID: RI-URBANS international OP interlaboratory comparisonQA1 date: 20230118 - 20230202QA1 document URL: 10.5194/amt-18-177-2025Originator: Jovasevic-Stojanovic, Milena, mjovst@vin.bg.ac.rsSubmitter: Petrovic, Bojana, bojana.petrovic@vin.bg.ac.rs Acknowledgement: "Data used in this <study/report/figure/etc.> were accessed from Zenodo. <include DOI in citation>. Specifically, the data included are affiliated with the framework of WeBaSOOP project (ID nr. 101060170). Request acknowledgement details from data originator"



